Salus Multi-Mix Operation And Installation Manual page 20

Weather controller
Table of Contents

Advertisement

Hydraulic scheme no. 2 - connection of a fireplace with a water jacket
Variant A – boiler with integrated pump, variant B – boiler without an integrated pump.
1 – boiler
2 – electrical switching servo with return spring
3 – coupling temperature sensor
4 – hydraulic coupling
5 – boiler pump
PROPOSED SETTINGS:
Parameter
Hydraulic diagram
Selection
Temp. deactivation of main heat
source
Pump start temperature (8)
Cooling temperature
Selection
Hydraulic diagram
Temp. deactivation of main heat
source
Pump start temperature (8)
Minimum temperature
Cooling temperature
Variant A: After heating the fireplace sensor (6) up to a temperature (35C) the boiler (1) is disabled along with an
integrated pump. After heating the sensor (6) up to a temperature (55C), valve (2) is switched and fireplace pump
(8) is enabled. When sensor (6) exceeds 92C, heat excess will be transferred to heat and HUW circuits.
Variant B: When a fireplace sensor (6) is heated up to a temperature of (35C), the boiler (1) turns off. After heating
sensor (6) up to a temperature of (55C), valve (2) switches over, pump (5) switches off and fireplace pump (8)
switches on. When sensor (6) exceeds 92C, heat excess will be transferred to heat and HUW circuits. When fireplace
(7) is cold, pump (5) switches off and on in accordance with indications of temperature sensor (3) and Minimum
temperature parameter settings.
2
Shown hydraulic diagram does not replace a central heating system and can be used only for demonstrative purposes
6 – temperature sensor of water inside the boiler with
water jacket
7 – fireplace with a water jacket
8 – water pump of the fireplace with water jacket
9 – thermostatic valve protecting return temperature.
Setting
2
menu→ service settings→System
ON
menu→ service settings→System→Additional heat source
35C
menu→ service settings→System→Additional heat source
55C
menu→ service settings→System→Additional heat source
92C
menu→ service settings→System→Additional heat source
ON
menu→ service settings→System→Additional heat source
2
menu→ service settings→System
35C
menu→ service settings→System→Additional heat source
55C
menu→ service settings→System→Additional heat source
50C
menu→ service settings→System→Additional heat source
92C
menu→ service settings→System→Additional heat source
20
2
.
MENU
!

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents