8

MAINTENANCE

8.1

Adjustments

For the appliance to operate correctly and efficiently it is
recommended that the User calls upon the services of a
Professionally Qualified Technician to carry out ANNUAL
maintenance.
m
CAUTION
– The maintenance interventions described must
ONLY be carried out the professionally qualified
personnel who MUST wear suitable protective safety
equipment.
– Make sure that the system components and pipes
are not hot (risk of burning).
a
WARNING
Before carrying out any interventions described:
– set the main system switch to "OFF"
– close the gas valve
– make sure that no hot parts inside the appliance are
touched.
OFF
8.2

External cleaning

8.2.1

Cleaning the cladding

When cleaning the cladding, use a cloth dampened with soap
and water or alcohol for stubborn marks.
d
IT IS FORBIDDEN
to use abrasive products.
8.3

Cleaning the inside of the appliance

m
CAUTION
External casing seals off the appliance from the
environment in which it is installed. Check regularly,
and always after performing maintenance work, that
the front, side and all gaskets have been correctly
closed and are not worn or damaged.
To clean the inside:
– remove the screws (1), pull the front panel (2) forwards and
release it from the top by lifting it
2
Fig. 52
8.3.1

Cleaning the air evaporator

– unscrew the eight screws (3) and remove the inspection cover
(4)
– use a hoover to remove any dirt.
1
Fig. 53
3
4
Fig. 54
43