Summary of Contents for Sime MURELLE REVOLUTION 25
Page 1
Cod. Wall-mounted hybrid condensing boiler MURELLE REVOLUTION 25 USER, INSTALLATION AND SERVICING INSTRUCTIONS Fonderie SIME S.p.A. 6328582 - 12/2017 - R3 TRANSLATION OF THE ORIGINAL INSTRUCTIONS...
Page 2
– The appliance must be used as intended by Sime that they are supervised or have been instructed who is not responsible for any damage caused to...
Murelle Revolution 25 25 8110290 USER INSTRUCTIONS COMPLIANCE TABLE OF CONTENTS Our company declares that Murelle Revolution 25 boilers comply with the following directives: – Gas Appliances Directive 2009/142/EC until 20/04/2018 – Gas Appliances EU Regulation 2016/426 from 21/04/2018 DESCRIPTION OF THE APPLIANCE –...
USER INSTRUCTIONS TABLE OF CONTENTS USING THE BOILER MURELLE REVOLUTION 25 MAINTENANCE Main control panel (remote)..... . . 6 Adjustments........12 External cleaning.
USING THE BOILER MURELLE REVOLUTION 25 Main control panel (remote) The main control panel (MCP) allows all of the necessary adjustments to be made to Murelle Revolution 25 and to the connected systems. It also serves as a main air thermostat and can therefore be used by all operators, users, authorised maintenance technicians and the technical service for the operations for which each of these figures is authorised, as described in detail in the relevant sections.
INFORMATION [...] protective gloves. TECHNICAL [...] Commissioning of the Murelle Revolution 25 boiler must be Back carried out by professionally qualified technicians, after which the boiler can operate automatically. It may, however, be Fig. 3 necessary for the user to start the appliance autonomously without involving a technician: for example, after a holiday.
Settings using the MODE button – press the click encoder to confirm the highlighted “Mode” From the “Main screen” : and go to the “rows” – Turn the encoder to “Boiler” Zone Thu 18 Set 2014 10:30 INFORMATION INFORMATION Zone heating [...] Zone heating [...]...
– turn the encoder to select the “Single days” or the “Group of days” Heating Function Mode Set AUTO comfort 20.0°C – press the click encoder to confirm the required selection Set AUTO reduced 18.0°C and access the first “Adjustable time” [1] Set MAN 20.0°C Program.
1.3.2 Holiday function : The user must work in a CIRCULAR manner, meaning NOTE This function allows the user to deactivate both heating and hot ALWAYS MOVING FORWARDS, even if a mistake is made. water production during a “set and activated” holiday period, during which the antifreeze function can be active (if set).
1.3.4 Quick settings – turn the encoder to set the new “Set value” The encoder allows the operator, specifically the user, to: – press the button to complete the modification Confirm – change the “Set hot water” in SUMMER mode and return to the “Main screen”...
MAINTENANCE DISPOSAL Adjustments Disposal of the equipment (European Directive 2002/96/CE) For the appliance to operate correctly and efficiently it is Once it reaches the end of its operating life, the equipment recommended that the User calls upon the services of a MUST BE RECYCLED in line with current legislation.
Page 13
DESCRIPTION OF THE APPLIANCE TABLE OF CONTENTS Main water circuit ......21 DESCRIPTION OF THE APPLIANCE Sensors .
After a set period of time, calculated using an algorithm probe is NOT connected, Murelle Revolution 25 will NOT work. according to the current outdoor temperature, the gas boiler The wall the appliance is mounted to must be able to support its...
Check and safety devices Identification The Murelle Revolution 25 boilers are equipped with the following The Murelle Revolution 25 boilers can be identified by means of: check and safety devices: Packaging label: this is located on the outside of the –...
4.4.1 Technical data plates Heat Pump Technical Data Plate Fonderie Sime SpA Legnago VR (Italy) Tel 0442 631111 POMPA DI CALORE ARIA/AQUA PER RISCALDAMENTO AIR TO WATER HEAT PUMP FOR HEATING SYSTEM Modello Matricola NAME SERIAL NUMBER SM16021614019 MURELLE REVOLUTION Alimentaz.
Structure Air inlet pipe Domestic hot water filter Gas boiler smoke evaporator Condensate siphon System relief valve Heat exchanger bleed point Diverter valve Boiler drain Heat exchanger System filling unit System pump Smoke flue gas probe Domestic hot water sensor Water pressure transducer Combustion chamber door Boiler control panel (gas side)
Page 18
System filling valve HP high pressure switch Condensate outlet HP high pressure switch Safety valve outlet Liquid level indicator Boiler connector (gas side) – Main Boiler drain control panel Thermostatic expansion valve HP-main control panel connector HP by-pass solenoid valve Fig.
Main water circuit Fig. 35 KEY: Pump M System delivery Automatic bleed valve R System return Pressure transducer U Domestic hot water outlet System expansion vessel E Domesti hot water inlet HP water inlet probe S Safety valve outlet System delivery valve (on request) G Gas supply Gas valve (on request) S3 Condensate outlet...
Sensors 4.10 Circulation pump The sensors installed have the following characteristics: The flow-head performance curve available for the heating – Dual sensor (thermal safety/output) NTC R25°C; 10kΩ β25°- system is shown in the graph below. 85°C: 3435 – domestic hot water sensor NTC R25°C; 10kΩ β25°-85°C: 3435 RESIDUAL HEAD (mbar) –...
pressing any one of these buttons for more than 30 NOTE: 4.11 Boiler control panel (gas side) seconds generates a fault on the display without preventing The boiler control panel can be used locally ONLY by the boiler operation. The warning disappears when normal technical assistance service or by an authorised maintenance conditions are restored.
4.13 Main control panel (remote) The main control panel (MCP) allows all of the necessary adjustments to be made to Murelle Revolution 25 and to the connected systems. It also serves as a main air thermostat and can therefore be used by all operators, users, authorised maintenance technicians and the technical service for the operations for which each of these figures is authorised, as described in detail in the relevant sections.
4.13.1 Using the buttons BUTTON (B) This allows users to view the “Function mode” screen (e.g. With the appliance powered, from the “Main screen” . “Winter”) and then to operate according to what is written above the button on the display (e.g. to exit and return to the main screen).
4.14 Wiring diagrams 4.14.1 Boiler BLACK BLUE BLUE BROWN BLUE BROWN BROWN 4 3 2 1 BLACK BROWN BLUE CN12 CN13 CN15 CN14 CN11 CD. 6324920 BLUE BLUE YELLOW - GREEN (#) GREEN BROWN TA TASE SE Line Neutral Fuse (3.15AT) Diverter valve Smoke flue gas probe System pump...
4.14.2 Heat pump BLACK BLACK BY-PASS BLACK BLACK 4 3 2 1 BLACK BLACK BLACK BLACK BROWN BLUE BLUE BLUE COMP BLACK BLACK RS485 COND BLACK BLACK BROWN BLUE 230 V - 50 Hz Heat pump fan Main control panel (remote) 24V power By-pass solenoid valve supply BY-PASS...
4.14.3 Interconnecting the appliance, outdoor probe and main control panel (remote) The connections below should be made by the installer and must be prepared before installing the main control panel (remote), See " Mounting the main control panel (remote)". OT OTSE SE Unpolarised cable Shielded polarised cable External sensor...
Page 29
5.12.3 Fitting the air ducts ....35 MURELLE REVOLUTION 25 5.12.4 Smoke outlet (Ø 80 mm)....36 PRODUCT DATA SHEET 5.13 Mounting the main control panel (remote) .
INSTALLATION CAUTION The appliance must only be installed by the Sime Technical Service or by qualified professionals who suitable protective safety equipment. MUST wear Receiving the product is delivered in a single unit protected by Murelle Revolution 25 cardboard packaging.
Fig. 52 New installation or installation of a replacement appliance When Murelle Revolution 25 boilers are installed on old systems or systems requiring updating, it is recommended the installer checks that: – the connecting flue pipe is suitable for the combustion...
In any case, please refer to and comply with Legislation and specific Technical Standards in force. Boiler installation Before mounting the Murelle Revolution 25 boiler on the wall, check that: – the wall is solid enough to support the weight –...
5.11 Gas supply boilers leave the factory prearranged for Murelle Revolution 25 gas G20 and can also work with G31 without the need for any type of mechanical conversion. Simply select parameter "03" (see “Parameter setting and display") and set the type of gas to be used.
Standards and Legislation in force. WARNINGS – The use of rigid ducts which are resistant to boilers must be installed and Murelle Revolution 25 temperature, condensate, mechanical stress and used with smoke outlet ducts and combustion/heat are air-tight is compulsory.
5.12.2 Holes for air inlet/outlet Two holes are required for the appliance in the wall to channel the air inlet (1) and outlet (2) pipes outside. ≈3° Fig. 61 WARNING When making the holes for channelling the inlet and outlet pipes outside, the majority of the material may be expelled outside;...
5.12.4 Smoke outlet (Ø 80 mm) Example calculation of the load loss of a smoke outlet for a boiler. Murelle Revolution 25 (installation permitted since the total of the load loss of the accessories used is less than 15 mm H2O ).
230V~50 Hz network. Fig. 67 If this cable needs to be replaced, an original spare must be requested from Sime . – refit the user interface (3) on the base (2), hooking the tab (1) DESCRIPTION CODE on correctly.
– press the click encoder to access the modifiable area. The requires an outdoor probe. This is supplied Murelle Revolution 25 following screen is displayed: and MUST be connected because the boiler uses the outdoor temperature detected to operate. CAUTION...
– turn the encoder to select the “Climatic curve ” row Summer Winter Zone heating Hot water MAN 40°C Req. from ext. TA Heating MAN 20.0°C Room probe run Room probe modul. Holiday function Ext. probe modul. Back Weather comp.curve ...
From the “Main screen” : – Press the click encoder to access the modifiable parameters area Zone Thu 18 Set 2014 10:30 Zone heating Req. from ext. TA Room probe run Room probe modul. Ext. probe modul. Menu Mode Weather comp.curve ...
Fig. 90 MULTI ZONE system – with zone valve and air thermostats. 5.15.1 REFILL operations The Murelle Revolution 25 boilers are not equipped with a filling valve which must be prearranged on the system return. The procedure is described below.
Domestic hot water circuit: 5.15.2 EMPTYING operations – open the isolation valves of the domestic hot water circuit (if Domestic hot water circuit: present) – close the domestic hot water circuit isolation valve – open one or more than one hot water valve to fill and bleed the (prearranged in installation) domestic hot water circuit –...
COMMISSIONING – Disconnect and reconnect the electrical power supply by Preliminary operations setting the main system switch to “OFF” and then to “ON” WARNING – Should it be necessary to access the areas in the bottom part of the appliance, make sure that the system components and pipes are not hot (risk of burning).
We recommend not changing the factory settings so – the values flash on the display: "100" (maximum value), as not to alter optimal appliance operation. For any followed by an "intermediate value" and finally "00" (minimum specific support, please contact the Sime Technical value) Assistance Service. 6.3.1 Settings using the MODE button From the “Main screen”...
Page 45
The fault may be transient (volatile) or it may cause an appliance block – turn the encoder to select “Heating” To restore normal operating conditions: – press the encoder to confirm “Heating” and access the – if the fault is transient, eliminate the cause of the fault “Rows”...
6.3.2 Navigating using the MODE button Modo: Inverno Progr. automatico - Set 18,0 Cfino alle 11:30 Menu Mode MODE To “select” rows or “modify” values click To “confirm” the selections or modifications Summer Winter Hot water HOLIDAY SCHEDULE Function mode MONTH YEAR Hour...
6.3.3 Settings using the MENU button – Turn the encoder and modify the “Data/value” in the 6.3.3.3 GENERAL SETTINGS menu permitted field (e.g. from ENG to ITA) From the “Main screen” on the main control panel (MCP) , proceed as follows: GENERAL SETTINGS Language Date and time...
Page 48
The “Display menu” allows the user to adjust: – display contrast – Press the click encoder to confirm the highlighted submenu – duration of the display back-lighting and access the modifiable area – encoder back-lighting The operating procedure is as has been described so far. SETTING DATE AND HOUR MONTH YEAR...
Page 49
CAUTION Fig. 124 We recommend not changing the factory settings so as not to alter optimal appliance operation. For any specific support, please contact the Sime Technical Assistance Service. – Turn the encoder to select the required submenu From the “Main screen” : –...
Page 50
CAUTION – Press the button to view the “Menu” selection Menu screen When the submenu “Boiler parameters” is selected, the following screen appears when the – turn the encoder to select the “TECHNICAL” menu click encoder is pressed: MENU GENERAL SETTINGS [...] ENTER ACCESS CODE INFORMATION...
Page 51
If the value of the selected parameter is to be modified: – Press the click encoder to confirm – Press the click encoder to access the value modification area CUSTOMER SERVICE NAME: PHONE: Boiler parameters Parameter Index: 1 1--------49 Parameter Value: 0 Cancel Confirm Fig.
6.3.4 Navigating using the MENU button Modo: Inverno Progr. automatico - Set 18,0 Cfino alle 11:30 Menu Modo MENU To “select” rows or “modify” values MENU MENU click To “confirm” the selections or modifications GENERAL SETTINGS [...] GENERAL SETTINGS [...] INFORMATION INFORMATION [...]...
Parameter setting and display – Turn the encoder to select the required submenu To access the parameters menu from the “Main screen” : – Press the encoder to confirm the selected submenu click and access the modifiable parameters area. Zone Thu 18 Set 2014 10:30 NOTE...
Page 54
CONFIGURATION Index showing boiler power in kW 5 = 25 (Murelle Revolution 25) 0 .. 6 6 = 30 (Murelle Revolution 25 30) Hydraulic configuration 0 = rapid 1 = storage tank with thermostat or heating only 0 .. 4...
Page 55
Type Description Range Step Default Domestic Hot Water Modulation with Flow meter 0 = Disabled 0 .. 1 1 = Enabled Maximum power domestic hot water 0 .. 100 Minimum power heating/domestic hot water (premixed) 0 .. 100 Domestic hot water preheating enabling 0 ..
Fault / malfunction codes Type Description Incorrect positioning of the delivery sensor If a fault occurs, the screen “Anomaly in progress” will appear EV2 SGV current max/min absolute limits error in place of the “Main screen” . For the main fault codes, a brief EV2 SGV current upper limit error description and suggestions for the user are displayed, based EV2 SGV current lower limit error...
TABLE OF INFORMATION DISPLAYED Display of operating data and counters Type Description Range Step Once the boiler is operating a qualified technician can view the SW version operating data and the counters as follows: - 9 .. – from the boiler control panel screen (gas side) in the mode External sensor °C or SUMMER...
Checks 6.7.1 Chimney sweeper function The chimney sweeper function is used by the qualified maintenance technician to check the mains gas pressure, detect the combustion parameters and to measure the combustion efficiency required by legislation in force. This function lasts 15 minutes and is activated by proceeding as follows: –...
Gas conversion to exit the "Chimney sweeper – press the button models can work with G20 or G31 Murelle Revolution 25 Procedure”. The boiler water delivery temperature will without the need for any mechanical conversion. Simply select appear on the display parameter "PAR 03"...
MAINTENANCE Adjustments Cleaning the inside of the appliance For the appliance to operate correctly and efficiently it is 7.3.1 Removing components recommended that the User calls upon the services of a Professionally Qualified Technician to carry out ANNUAL To access the internal parts of the boiler: maintenance.
– remove the two screws (7), lift the expansion vessel and hook – Unscrew the four nuts (14) securing the combustion chamber it onto the support (8) door (15) – pull the fan/sleeve/door/air pipe assembly (16) forwards and remove it. Fig.
7.3.4 Cleaning the smoke exchanger Checks Remove the cover (17) by unscrewing the two screws and remove any carbon deposits. 7.4.1 Checking the smoke duct Check that the combustion air inlet/outlet ducts and smoke outlet duct are integral and airtight. 7.4.2 Checking the expansion vessel pressure It is recommended that the expansion vessel on the water side...
/sealed (Combustion configuration) to 0 Index showing boiler power in kW 5 = 25 (Murelle Revolution 25) chamber 6 = 30 (Murelle Revolution 25 30) - Replace the smoke probe Smoke probe Hydraulic configuration - Contact the Technical...
Page 64
Heat pump fault Type Fault Solution Type Description Solution - Check electrode Unstable Automatic reset - Check outlets combustion Remove and reconnect - Check air diaphragm (for BF High pressure feedback signal the electrical power models) error supply - Check gas calibration Automatic reset - Check electrode Remove and reconnect...
Page 65
CHECKLIST MURELLE REVOLUTION 25 The Murelle Revolution 25 boiler must be installed and commissioned solely by qualified companies or by professionally qualified technicians as specified in the appliance manual. INSTALLATION N° Description Read the appliance manual supplied. Check that the installation location/room and chosen wall are suitable for the appliance type and weight.
Page 66
PRODUCT DATA SHEET MURELLE REVOLUTION 25 Seasonal energy efficiency of heating from heat pump [“I”] (%) Temperature control contribution (%) Additional boiler contribution (%) Solar energy contribution (%) Energy efficiency class of combined central heating Seasonal energy efficiency of combined central heating (%) Weighting factor of preferential heating appliance heat output [“II”]...
Page 68
Fonderie Sime S.p.A - Via Garbo, 27 - 37045 Legnago (Vr) Tel. +39 0442 631111 - Fax +39 0442 631292 - www.sime.it Fonderie SIME S.p.A. reserves the right to make changes at any time without prior notice in order to improve its products without compromising the essential characteristics.
Need help?
Do you have a question about the MURELLE REVOLUTION 25 and is the answer not in the manual?
Questions and answers