3 Technical specifications
3
Technical specifications
3.1
Homologations
3.2
Technical data
Tab.1
Conditions of use
AWHP 4.5 MR
Limit water op
+18 °C/+55 °C
erating temper
atures in heat
ing mode
Limit outdoor
-15° C/+35 °C
air operating
temperatures in
heating mode
Limit water op
+7 °C/+25 °C
erating temper
atures in cool
ing mode
Limit outdoor
+7 °C/+40 °C
air operating
temperatures in
cooling mode
Tab.2
Heating mode: outside air temperature +7°C, water temperature at the outlet +35°C. Performances in accordance with
EN 14511-2.
Measure
Unit
ment type
Heat output
kW
12
MIV-4S
3.1.1
This product complies with the requirements of the following European Di
rectives and Standards:
This product conforms to the requirements of European Directive
2009/125/EC on the ecodesign of energy-related products.
In addition to the legal requirements and guidelines, the supplementary
guidelines in this manual must also be followed.
Supplements or subsequent regulations and guidelines that are valid at
the time of installation shall apply to all regulations and guidelines speci
fied in this manual.
3.2.1
Maximum operating pressure: 0.3 MPa (3 bar)
AWHP 6 MR-3
+18 °C/+60 °C
-15° C/+35 °C
+7 °C/+25 °C
+7 °C/+40 °C
AWHP 4.5
AWHP 6
MR
MR-3
4.60
5.82
Directives
Pressure Equipment Directive 2014/68/EU
Low Voltage Directive 2014/35/EU
Generic standard: EN 60335-1
Relevant standards: EN 60335-2-21, EN 60335-2-40
Electromagnetic Compatibility Directive 2014/30/EU
Generic standards: EN 61000-6-3, EN 61000-6-1
Relevant Standard: EN 55014
Heat pump
AWHP 8 MR-2
+18 °C/+60 °C
-20° C/+35 °C
+7 °C/+25 °C
+7 °C/+40 °C
AWHP 8
AWHP 11
MR-2
MR-2
7.9
11.39
AWHP 11 MR-2
AWHP 16 MR-2
AWHP 11 TR-2
AWHP 16 TR-2
+18 °C/+60 °C
+18 °C/+60 °C
-20° C/+35 °C
-20° C/+35 °C
+7 °C/+25 °C
+7 °C/+25 °C
+7 °C/+40 °C
+7 °C/+40 °C
AWHP 11
AWHP 16
TR-2
MR-2
11.39
14.65
7682850 - v02 - 09012018
AWHP 16
TR-2
14.65