Reading Out Measured Values - DeDietrich MIV-4S AWHP 6 MR-3 User Manual

Reversible air/water "split inverter" heat pump
Table of Contents

Advertisement

7

Reading out measured values

Tab.24
List of sub-menus
Sub-menu
001
002
003
Tab.25
Values available (X) in the EHC--04, SCB04-B sub-menus
Parameter
Description
AM002
AM010
The current pump speed
AM012
Current main status of the appliance.
AM014
Current sub status of the appliance.
AM015
Is the pump running?
AM016
Flow temperature of appliance.
AM019
Water pressure of the primary circuit.
AM027
Instantaneous outside temperature
AM040
Temperature used for hot water control algorithms.
AM056
Wate flow rate in the system
AM091
Seasonal mode active (summer / winter)
0: Winter
1: Frost protection
2: Summer neutral band
3: Summer
AM101
Internal system flow temperature setpoint
CM030
Measure of the Room temperature of the zone
CM040
Measure Zone Flow Temperature or DHW
temperature
CM060
Current Pump speed of zone
CM120
Zone Current Mode:
0 =Scheduling
1
=Manual
2 =Antifrost
3 =Temporary
7682850 - v02 - 09012018
Description
EHC-04 central unit PCB
SCB-04 secondary circuit PCB
HMI control panel
See
See following table
See
See following table
The measured values are available in the Information
ferent PCBs.
Certain parameters are displayed:
according to certain system configurations,
according to the options, circuits or sensors actually connected.
Unit
%
°C
bar
°C
°C
l/min
°C
°C
%
7 Reading out measured values
menu of the dif­
Name of the PCB or circuit
EHC--04
SCB04-B
HMI
EHC--04
SCB04-B
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
MIV-4S
39