2-12.

DCP-56 Board

Preparation
1.
Remove the battery lid. (Refer to
2.
Remove the bottom cover. (Refer to
3.
Remove the inside panel assembly. (Refer to
4.
Remove the outside panel assembly. (Refer to
5.
Remove the top panel assembly. (Refer to
6.
Remove the SxS slot assembly. (Refer to
7.
Remove the front panel assembly. (Refer to
8.
Remove the rear panel assembly. (Refer to
9.
Remove the CN-3540 board. (Refer to
10. Remove the IO-255 board. (Refer to
Procedure
1.
Remove the four precision screws (M2 x 4) to detach the HDMI bracket.
2.
Disconnect the coaxial cable from the connector CN2200 on the DCP-56 board.
Precision scews
(M2 x 4)
3.
Remove the six precision screws (M2 x 4) to detach the main heat spreader DCP.
4.
Disconnect the harness from the connector CN2301 on the DCP-56 board.
5.
Disconnect the HN-387 board from the connector CN2300 on the DCP-56 board.
6.
Disconnect the HN-384 board from the connector CN2402 on the DCP-56 board.
7.
Disconnect the three fine-wire coaxial cables from the three connectors CN001, CN303 and CN305 on the DCP-56
board.
PMW-200/PMW-EX280
"2-2. Lithium
Battery".)
"2-3. Bottom Cover and Tripod
"2-4-1. Inside Panel
"2-5-1. Outside Panel
"2-6. Top Panel
"2-7-1. SxS Slot
"2-8-1. Front Panel
"2-9. Rear Panel
"2-10. CN-3540
"2-11. IO-255
Board".)
CN2200
DCP-56 board
Coaxial cable
Washer".)
Assembly".)
Assembly".)
Assembly".)
Assembly".)
Assembly".)
Assembly".)
Board".)
HDMI bracket
Precision screws
(M2 x 4)
2-22