10. Remove the main heat spreader DCP. (Refer
11. Remove the handle assembly. (Refer to
12. Remove the front lens assembly. (Refer to
Procedure
1.
Disconnect the harness from the connector CN202 on the RE-298 board.
2.
Disconnect the harnesses from the connectors CN100 and CN101 on the RE-299 board.
3.
Remove the five precision screws (M2 x 4).
Note
When installing these precision screws, push the U groove of the bracket AU against the positioning pin, and tighten
the screws in the order of numbers shown in the figure.
4.
Disconnect the HN-386 board from the connector CN104 on the AU-342 board.
5.
Disconnect the AU-342 board from the connector CN2400 on the DPR-343 board.
CN2400
(DPR-343 board)
HN-386 board
Positioning pins
U groove
U groove
6.
Remove the precision screws (M2 x 4).
PMW-200/PMW-EX280
to"2-12. DCP-56
"2-13-1. Handle
Assembly".)
"2-14-1. Front Lens
CN202
CN104
2
Precision screws
(M2 x 4)
AU-342board
Board".)
Assembly".)
RE-298 board
RE-299 board
CN101
CN100
3 Precision screws
(M2 x 4)
1
Precision screw
(M2 x 4)