Sony PMW-200 Service Manual page 93

Solid-state memory camcorder
Hide thumbs Also See for PMW-200:
Table of Contents

Advertisement

ID
Diagnosis
0x09  
2
I
C communication test (I/O expand-
er)
0x0a  
Version matching test (power supply
microcomputer)  
0x0b  
Version matching test (sub-micro-
computer of the inside panel)
0x0c  
Version matching test (sub-micro-
computer of the handle)
0x0d  
Version matching test (sub-micro-
computer of the rear panel)
0x0e  
Version matching test (sub-micro-
computer of the outside panel)
0x0f  
Version matching test (sub-micro-
computer of the viewfinder)
Item6 (Power block diagnosis)
The power block diagnosis tests the following contents.
ID
Diagnosis
0x01  
Power switch read  
0x02  
Battery recognition  
0x03  
Power supply state  
Item7 (Diagnosis between image processor and display block)
Diagnosis between the image processor and the display block tests the following content.
ID
Diagnosis
0x80
Video signal line test
PMW-200/PMW-EX280
Error value
-1: Error
-1: Error
-1: Error
-1: Error
-1: Error
-1: Error
-1: Error
Error value
-1: The power switch cannot be read.
-4: Diagnosis is disabled because the
power switch is not set to ON.
-1: Communication with battery is
disabled.
-4: Diagnosis is disabled because no
battery is connected.
-1: Power supply is not controlled
correctly.
-4: Diagnosis is disabled because the
power switch is not set to ON.
Error value
-1: Test pattern check error
Type1/2
Note
1, 2  
The unit must have started
and a sub-microcomputer
must be connected.
1, 2  
The unit must have started
and a sub-microcomputer
must be connected.
1, 2  
The unit must have started
and a sub-microcomputer
must be connected.
1, 2  
The unit must have started
and a sub-microcomputer
must be connected.
1, 2  
Normal end "0" is always re-
turned because there is no ap-
plicable device in this unit.
1, 2  
Normal end "0" is always re-
turned because there is no ap-
plicable device in this unit.
1, 2  
Normal end "0" is always re-
turned because there is no ap-
plicable device in this unit.
Type1/2
Note
1, 2  
The power switch must
be set to ON.
1, 2  
An appropriate battery
must be connected.
1, 2  
The power switch must
be set to ON.
Type1/2
Note
1, 2
Video signal line test between
the camera signal processor IC
and the baseband processing IC.
Monitor output images will be
distorted during the test.
3-11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pmw-ex280

Table of Contents