Error value
Diagnosis
10
Path: Pin L1 → pin P7
Data: sine wave (1 kHz)
Starting serial input channel: Channel 1
Starting serial output channel: Channel 1
Error values of diagnosis items ID 0x15
Note
The signal is input to IC501 (pin M14) on the AU-342 board and is output from IC501 (pin number: shown below) to
IC1700 on the DCP-56 board (pin number: shown below).
Error value
Diagnosis
1
Path: Pin A2 → pin G22
Data: 0x55550000
Starting serial output channel: Channel 4
2
Path: Pin A2 → pin G22
Data: 0xaaaa0000
Starting serial output channel: Channel 4
3
Path: Pin A3 → pin H22
Data: 0x55550000
Starting serial output channel: Channel 6
4
Path: Pin A3 → pin H22
Data: 0xaaaa0000
Starting serial output channel: Channel 6
Item5 (System controller block diagnosis)
The system controller block diagnosis tests the following contents.
ID
Diagnosis
0x01
I
2
C communication test (RTC)
0x02
2
I
C communication test (EEPROM)
0x03
2
I
C communication test (power sup-
ply microcomputer)
0x04
2
I
C communication test (sub-micro-
computer of the inside panel)
0x05
2
I
C communication test (sub-micro-
computer of the handle)
0x06
I
2
C communication test (sub-micro-
computer of the rear panel)
0x07
I
2
C communication test (sub-micro-
computer of the outside panel)
0x08
I
2
C communication test (sub-micro-
computer of the viewfinder)
PMW-200/PMW-EX280
Error value
-1: Error
-1: Error
-1: Error
-1: Error
-1: Error
-1: Error
-1: Error
-1: Error
Type1/2
Note
1, 2
The unit must have started
and a sub-microcomputer
must be connected.
1, 2
The unit must have started
and a sub-microcomputer
must be connected.
1, 2
The unit must have started
and a sub-microcomputer
must be connected.
1, 2
The unit must have started
and a sub-microcomputer
must be connected.
1, 2
The unit must have started
and a sub-microcomputer
must be connected.
1, 2
Normal end "0" is always re-
turned because there is no ap-
plicable device in this unit.
1, 2
Normal end "0" is always re-
turned because there is no ap-
plicable device in this unit.
1, 2
Normal end "0" is always re-
turned because there is no ap-
plicable device in this unit.
Continued
3-10