KEB Combivert F5 series Instruction Manual page 16

0.5...200 hp
Hide thumbs Also See for Combivert F5 series:
Table of Contents

Advertisement

Technical Data
Technical Data 230V Class Continued
Inverter Size
Recommended Motor Power
Housing size
Input Ratings
Supply voltage frequency
Rated input current
Recommended maximum input fuse
Recommended wire gauge
Output Ratings
Rated output power [kVA]
Rated motor power [kW]
Rated output current
Peak current (30 seconds)
Over current fault (E.OC) trip level
Overload curve (see annex)
Rated switching frequency [kHz]
Maximum switching frequency [kHz]
Power loss at rated operation
Stall current at 4kHz
Stall current at 8kHz
Stall current at 16kHz
Braking Circuit
Min. braking resistance
Typ. braking resistance
Max. braking current
Installation Information
Max. shielded motor cable length
Tightening torque for terminal strip [in lb]
Environmental
Max. heat sink temperature TOH
Storage temperature
Operating temperature
Housing design / protection
Approvals
Tested in accordance with...
Standards for emitted interference
Standards for noise immunity
1) With the regulated systems F5-M as well as F5-S 5% must be subtracted as control reserve
3) The wire gauge is based on the maximum fuse rating, copper wire with minimum 75°C insulation rating, THHW or equivalent.
If branch circuit protection is selected based on rated input current, the wire size could be reduced.
4) This data is only valid for units with internal brake transistor GTR 7 (see "unit identification")
5) The maximum cable length is the same for all carrier frequencies.
6) Contact KEBCO for this specifications.
7) Rated operation means, rated input voltage, rated output current, and rated carrier frequency.
[hp]
Supply voltage
[V]
[Hz]
Input phases
[A]
[A]
3)
[awg]
[A]
1)
[A]
[A]
[V]
Output voltage
Output frequency
[Hz]
7)
[W]
[A]
[A]
[A]
4)
[Ohm]
4)
[Ohm]
[A]
5)
[ft]
[°C]
[°C]
[°C]
Relative humidity
Climatic category
15
16
15
20
G
H
H
180...260 ±0 (230 V rated voltage)
3
3
46
59
50
60
80
8
6
4
17
23
11
15
18,5
42
54
72
99
88
119
3 x 0...V input (3 x 0...255V
Generally 0 to 1600Hz (limited by control board and carrier frequency)
4
16
16
4
16
16
330
430
550
36
48
66
-
48
66
-
48
66
13
5,6
5,6
16
13,6
8,8
29
70
70
330
11
22
-25...70 °C / -13...158°F
-10...45 °C / 14...113°F
max. 95% without condensation
EN 61800-3 /UL508C
EN 55011 Class B / EN 55022 Class A
IEC 1000-4-2 / -3 / -4 / -5/ -6
3K3 in accordance with EN 50178
17
18
19
25
30
40
R
R
R
50 / 60 +/- 2
3
3
3
75
88
114
100
100
125
3
3
1
29
35
42
22
30
68
80
104
126
150
172
135
162
207
1
2)
)
8
8
8
16
8
8
850
1020
1200
84
100
115
84
100
115
50
-
-
4,7
4,7
3,3
5,6
5,6
4,7
88
88
133
165
53
90°C / 194°F
Chassis / IP20
20
21
50
60
R
R
3
3
143
169
175
200
2/O
3/O
52
62
37
45
130
154
225
270
270
315
8
8
8
8
1400
1700
150
180
150
180
-
-
2,5
2,5
3,9
3,0
160
160