3) Click a section "PID" ... "CC" to select the analysis method
to be used. If the camera does not support the analysis
method selected, the following message will appear at
the bottom of the menu:
intelligent setup.
Parameter
Record Search
Maintain
Channel
Events
Enable
Sensitivity
Intelligent
Area
Schedule
Post Recording 30 s
PID
Alarm Out
Show Message
LCD
Record Channel
SOD
1
2 3 4
PD
FD
CC
Fig. 7-35 Settings for intelligent image analysis
Menu item
Channel
Enable
Buzzer
Sensitivity
Scene
Area
Post Recording
Latch Time
Alarm Out
Show Message
Send Email
Full Screen
48
This camera doesn't support
i
Device
System
Advance
CH1
Enable
Buzzer
Disable
1
Scene
Indoor
Setup
Latch Time 10 s
Send Email
Full Screen
Default
Function
To select a camera channel
To enable or disable the analysis feature
Duration of the alarm sound:
Disable, 10 s, 20 s, 40 s, 60 s
Sensitivity of the analysis feature (1 – 4);
the higher the value, the more sensitive the
analysis feature
Location of the camera: indoor or outdoor
Click
Setup
to define up to 4 detection fields.
1. Click the left mouse button to define the
four corners of a field. Make sure that there
is no notch in the field; otherwise, an error
message will be shown.
2. To activate the field: In the menu to the left
of the image, set the line "Rule Switch" to
"Enable".
3. In the line "Rule Type", define the motion
direction that is to trigger an action:
A->B = motion going into the field
B->A = motion going out of the field
A<->B = motion into both directions
4. To change a field, click the red square to the
left of the field number. Keep the left mouse
button pressed and move the corners of
the field. To move the entire field, place the
mouse pointer into the field and keep the
left mouse button pressed.
5. To save the settings, click "Save".
6. To remove all fields, click "Remove All"; to
remove the field selected, click "Remove".
7. To go back to the menu, click the right
mouse button in the camera image.
Duration of a recording that has been started
by the analysis feature
When an event is detected by the analysis
feature, the alarm relay (output ALARM or OUT,
chapter 6.4) will respond for the time defined
When this field has been tick-marked:
The alarm relay will respond when an event is
detected by the analysis feature
A detected event will be indicated by the icon
S
in the live image; the icon will appear in a red
field when recording has been started by the
detected event.
When an event is detected, an e-mail will be
automatically sent provided that the required
specifications have been made in the menu
"Parameter", submenu "Network", section
"Email".
The corresponding channel will be displayed in
the full-screen mode.
Menu item
Record Channel
Default
Save
Shutdown
Cancel
4) Depending on the analysis method selected, you can
either select fields (methods PID, SOD, PD and FD) or lines
( methods LCD and CC) when you click
IMPORTANT: For an analysis with clear results, make sure
that
– the fields or lines are not too close to the edges of the
Save
Cancel
image
– the fields are not too small and the lines are not too short
– the fields or lines are not masked (Parameter  Display
 Privacy Zone)
5) To show a list of events, click the icon
corner of the screen.
7.16 Saving and loading
different configurations
It is possible to save different recorder configurations for dif-
ferent users or fields of applications (e. g. to a USB flash drive)
and to load them when required.
1) Connect an external storage device (flash drive/hard disk)
to one of the two USB ports of the recorder.
2) Configure the recorder as desired.
3) Call up the menu "Advanced"; the submenu "Maintain"
will appear:
Parameter
Maintain
Events
Intelligent
Fig. 7-36 Menu "Advanced", submenu "Maintain"
4) Click "Save Settings". The window "Save Settings" will ap-
pear. Make the settings for saving and click "OK". The name
"NVR_Settings" will be assigned to the configuration file.
5) If you have more than one configuration, save the config-
urations to different folders to make sure that a recorder
configuration already saved will not be overwritten.
6) To load a configuration, click "Load Settings".

7.17 Tips

Tip
To automatically set the recorder
for daylight saving time
To automatically set the time via
the network
To automatically send an e-mail in
case of an alarm
Function
Specification of the channels that are to be
recorded when an event is detected
(it is possible to record multiple channels even
if the event has been detected in one channel
only).
Reset to factory settings
To save the setting
To exit the menu
i
Record Search
Device
System
Default User
admin
Auto Reboot
Enable
Reboot
Every Week
Sun.
Update
Load Default
Load Settings
Save Settings
IPC Load Default
Reboot IPC
Menu path
System  General  DST
System  General  NTP
Parameter  Network  Email
.
Setup
in the upper right
Advanced
Shutdown
00:00
IPC Upgrade
Default
Save
Cancel

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Ior-208Ior-232poeIoz-204bvIoz-204dvIoz-408bvIoz-408dv

Table of Contents