[Cooling control cycle setup]
▶COOL(cooling control) is briefly shown and 0h(hour) sign flickers.
Setup the desired cooling control cycle with + and - button and press OK to move to
number of hatching days setup phase.
[Adjustment scope : 0 ~ 6h(hours) in 1 hour as a unit]
[Default value : 0h(hour)]
What is COOL(cooling control) Function? It is a function which cools during the setup
time
among the 24 hours of a day. The periodic cooling is helpful for successful hatching but
you might need preliminary knowledge to perform the cooling control process.
[Setup of number of incubation days (D-Day)]
▶ DAY(number of hatching days) and D-25 are shown.
Setup the desired number of days with + and - button and press OK to save setup value
and
initiate incubation.
[Adjustment scope : 1 ~ 50 days]
▶ If Candling sign(button) was pressed during setup you can go back to previous step.
▶ How to setup continuous incubation function : In D-Day(number of hatching days) setup
use the + button and increase until D-50Days and press + again and "--" sign is shown,
and by pressing OK button it is setup as continuous incubation function.
What is Continuous Incubation Function Setup?
It is a function which enables the continued operation of the device with the currently setup incubation conditions regardless of number of incubation
days.

How to manually Humidify and Supply Water in Rcom PRO 10

▶ Pour water into water hole of the main body (lower part). The connected silicone hose will
supply water to the interior.
▶ Verify daily if there is water in the water hole during incubation and supply when
insufficient.
▶ When desiring to incubate on low humidity only fill the internal water chamber A
connected
to the water hole. [RH 45% or less]
If the humidity of hatching chamber is higher than setup value please open the air control
▶ When desiring to incubate with high humidity, please fill all the A and B water chambers
with
water. [RH 45% or over]
Adjust humidity 3 days before hatch.
If the humidity is lower than setup value please close the air control lever.
(Reference the humidity and ventilation control during incubation)
(Reference
the 3. Incubation/Function setup → (3) Humidity and ventilation control during
incubation)

Termination of incubation

▶ During incubation '-' press the *which button?* button for 3 seconds and the incubation is terminated and moves to initial step/status.

Resetting incubation environment during incubation

▶ Press the + and - buttons at the same time during incubation to Reset incubation
environment and the temperature sign flickers.
▶ When modifying the temperature readjust the value with + and - buttons, press OK button
and the setup value is saved and it moves to next step (temperature, humidity, egg
rotation,
egg rotation cycle, order of hatching days).
▶ If Candling sign(button) is pressed during setup you can go back to previous step.
Also the display switches to incubation display if a button is not pressed during 10
seconds.

High/Low temperature Alarm function (optional function)

What are Abnormal High/Low Temperature Alarm functions?
It is an Alarm Function which notifies the user when the device's interior temperature is abnormally high or low.
▶ The alarm sounds in case of abnormal temperature and the display shows the current
temperature and consequently whether it is high or low according to the setup value.
The alarm sounds for 1 minute and automatically stopped, and the alarm sign is consequently shown until the OK button is pressed.
Ex : In case of alarm for 2℃ HI it consequently shows the current temperature and +2.0 / In case of '-3℃ LO alarm it consequently shows current
temperature and -3.0.
[How to setup Abnormal High Temperature Alarm]
▶ Setup scope : 0.0 ~ 5.0℃ (0 ~5℉), Default setup value : 2℃
▶ By pressing the + and OK buttons for 3 seconds at the same time the OPTN(option) sign
appears.
Rcom Bird Egg Incubator Eco Pro Plus 10 User Manual
:
It is an alarm function which notifies when the device's interior temperature is higher than setup value.