Symptom
If the power is not on
If the temperature is
too high / low
If the humidity is too high
/ low
It produces noise.
* There is certain level of noise due
to the fan for air circulation within
the device.
When dews are formed
within the device
* When maintained in high
humidity there may be formed
dews.
Please verify if every function of the device is performed properly by operating sufficiently the device before locating the eggs.
In case of incubation of costly eggs you might need check-up or adjustment of internal temperature to prevent failure of incubation. In the
checkup or examination please use a high-reliability thermo-hygrometer. (RCOM Digilog3 model or higher)
5. PRODUCT INFORMATION
Specification
Rated voltage
Power consumption
Temperature adjustment scope
Capacity
Weight of product
Size of product
Rcom Bird Egg Incubator Eco Pro Plus 10 User Manual
▶ If the setup temperature is too high.
▶ If the egg rotation is not performed.
▶ In case of unhealthy hatchery egg.
▶ If the setup temperature is too low.
▶ Difference of hatchery egg storage time.
▶ Occurred from the diversity of hatching temperature.
▶ The hatching rate is lowered as the days to hatch are
different
For more detailed self-troubleshooting, verify the "Troubleshooting" category in the Rcom web site.
Estimated cause (possibility)
▶ Verify if the power cord is correctly inserted.
▶ Verify if there is no power failure/blackout.
▶ Verify if the plug is faulty or not.
▶ Verify if the power cord and pump power cord locations
are
▶ Verify the setup temperature.
▶ Verify if the air circulation FAN does not rotate.
▶ Verify if there is enough water.
▶ Verify the setup humidity.
<If it's too low>
▶ Verify if the water is insufficient or not.
▶ Verify if the view-window is correctly closed.
<If it's too high>
▶ Verify the nearby environment.
▶ Verify if there is any water inside the tray or in the bottom
body.
▶ Verify if there is any object on the device.
▶ Verify if there is any vibration on the floor or the device
was
installed on a table.
▶ Verify if there is any alien substance around the FAN after
▶ Verify if the surrounding temperature of the installed place
is too low.
DC 12[V] 3[A]
Max 36[W] Average 21[W]
33 ~ 39 [℃] / 91.4 ~ 102.2 [℉] (May vary according to surrounding environment)
In case of egg 10 ~ 15[units], in case of quail egg 30 ~ 48[units]
N.W. 1.3[Kg], G.W 2.3[kg]
(w)259 x (L)236.5 x (H) 172 [mm]
▶ Slightly decrease the temperature of the device. [0.5°C (1°
F)] Ex) 37.5°C
→ 37.0°C
▶ Initiate egg rotation test verifying if the egg rotation
function is not OFF.
▶ Slightly increase the temperature of the device. [0.5°C (1°F)]
Ex) 37.0°C
37.5°C
▶ When possible, minimize the egg storage period/time.
▶ Check the temperature difference within the device.
(sunlight and temperature of hatching room, etc)
▶ Mark the hatching date on the egg and move to other
device (generator) according to the estimated hatching
date.
▶ It is convenient if you have other additional devices which
can be used as generator chamber when different eggs are
placed together at the same time.
Measures
▶ Insert correctly the power cord again.
▶ Verify other nearby electronic and electric devices.
▶ Verify and try other power socket.
▶ Insert after verifying the correct location.
▶ Adjust the temperature setup to desired temperature.
▶ Disconnect the power plug from the socket, separate the
main body and brush or clean the air circulation FAN.
▶ Supply enough water.
▶ Adjust the desired humidity in setup.
▶ Try the factory initialization.
<If it's too low>
▶ Supply water.
▶ Verify if there is any alien substance and close again.
<If it's too high>
▶ Adjust the environment of the incubator.
▶ Eliminate the water inside the tray.
▶ Remove all the objects from the top of the device.
▶ Install the device in other stable place.
▶ Disconnect the power plug from the socket, separate the
main body and brush/clean the FAN for air circulation.
▶ Please install in a place within the conditions of an
incubator.
(3) Product data / Product warranty
(4) Guide on Customers' Damage Compensation

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PRO PLUS 10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Pro 10Eco plus 10Eco 10

Table of Contents