Rcom PX-20RD User Manual

Reptile incubator

Advertisement

Quick Links

1. Safety Cautions
Electrical hazards
Do not use a damaged
Do not pull the cord when
taking out the power cord,
power cord or loose
and keep wet hands away
outlet.
from connecting plug.
Risk of electric shock or fire.
Risk of electric shock or fire.
Setting Cautions
Do not install in dusty or
Do not install under the
dirty environment.
direct sunlight.
Risk of damage or fire within
Risk of fire or interference with
the incubator.
the incubation process.
Do not cover the
Install away from heat
ventilating opening.
sources.
Inner temperature can rise,
Risk of damage to the incubator
interrupting incubation.
case and interference with
the incubation process.
Do not disassemble or
Please ensure that no
modify the incubator in
small objects get into
any way.
the holes on the incubator.
Risk if electric shock or fire.
Risk of electric shock or fire.
Cleaning Cautions
Do not spray cleanser
Clean the incubator by a
directly on the incubator
soft cloth with a neutral
surface.
detergent.
2. Identification of Parts
Vents for air circulation
For circulating warm air
Air inlet vent
For inlet of air
from outside
View Window
For a clear view of
the incubation process.
( duplicated View Window )
Digital Control Center
See description of
the function and operation.
Locking Button
3. Basic Components
Main Body-1
Main Body-2
Water Cap
View Window
4. How to Assemble
Insert the power cord
View Window
in the socket at the back
of the main body.
Tray
Main Body-1
Main Body-2
Lock the three locking
buttons at the front and rear
of the incubator.
professional
PX-20RD
www.R-com.co.kr
USER'S MANUAL
(Professional)
Be careful the details below when you use.
Never pull the plug out of
Do not twist or crush
Do not insert multiple
the outlet during the
electric cord.
connecting plugs in an
incubation period.
outlet.
Incubation will be interrupted.
Risk of electric shock or fire.
Risk of fire or electrical overload.
Be careful the details below when you use.
Do not install in moist or
Do not install in excessively
Do not use any other
humid environment.
cold or hot conditions,
non-standard parts
cigarette smoke, etc.
except those provided.
Risk of fire or electric shock.
Risk of interference with
Risk of damage or hatching
the incubation process.
failure.
Ensure that the incubator is
Do not turn the incubator
Do not install where
installed on a stable surface
upside down.
children or other people
away from edges.
can touch with easy.
Risk of damage to incubator
Water will pour out of the incubator,
Risk of knocking the incubator
and eggs and user from
and view window can be dropped
or accidental interference with
accidental knocks or drops.
or damaged.
the controls.
If the incubator sounds
Clean the incubator
If the incubator requires
strange or emits smoke
thoroughly before storing.
repair disconnect from the
contact your service
power supply and please
center.
contact to your service center.
Risk of electric shock or fire.
Be sure to disconnect the electric cord
from the outlet before cleaning.
Brush away dust on the
Do not use chemicals like wax,
For special cleaning of
inner part per year, contact
plug with a dry cloth.
benzene, alcohol, thinner,
to the service center.
aromatic, or lubricant, etc.
Power Connecting
For connecting
power cord.
Tray for Vermiculite
(incubation sand)
and reptile eggs.
Main Body-1
Main Body-2
User's Manual
Tray
5. How to Replace Fuse
▶ When the machine failed to
power on even if you pluged in,
remove the fixing piece like
the picture by screwdriver.
▶ You can find assembled PCB
when open the cover.
Remove faulty fuse with screwdriver.
▶ Replace with new fuse.
( 250V 2.0A Ø5*20mm )
6. Before use
Digital Incubator
Environment conditions of the incubation room
for the installation of reptile incubator.
( Temp.: 22~25℃ / Humidity: 30~50% )
If the incubation room temperature does not meet
the required temperature, it can not be controlled
automatically with the set incubation conditions.
Room temperature should be about 4℃ lower
than incubator setting temperature.
▶ In case of low humidity incubation (70% ~ 85%) Fill the vermiculite(incubation sand) which
is to be purchased separately into the small incubating tray as shown in [Fig.- 1] ⓑ.
▶ In case of high humidity incubation (90% or more) In case the incubating environment is to be maintained 90%
or higher in humidity, fill the small incubating tray with 900cc of water as shown in [Fig.- 1 ] ⓐ and
put the vermiculite into it as shown in [Fig.- 1 ] ⓑ before mixing them. That would facilitate the control of
high humidity and remove the need of water filling.
1. Before starting incubation, fill water into the water tankⓒ,ⓓ of main body-2
as [ Fig.-2 ] for humidification.
Remove water from the tank before moving the incubator.
Otherwise the incubator can be out of order.
2. Humidification heater part [ Fig.-5] of the main body-1 should be soaked
inside of water tank when assembling with main body-2.
Be sure to check this, and cover the view window for connecting power cord.
▶ If you are going to incubate without water in the incubator,
you should turn off humidification function.
(Refer to How to turn off Humidification Function)
Do not apply force or shock to heater on the upper part of the body.
It may be the cause of failure.
Some foreign body can be stick to the heater part after hatching,
but there is no problem. (Refer to the "How to Clean)
3. After setting the incubation environment of the egg, install tray
inside of the incubator and operate it for 30 to 40 minutes
and put eggs into the tray.
4. Bury a low half of the eggs into the Vermiculite as[Fig.-1] and fix them.
(Check the conditions of the eggs once a week. Remove unfertilized eggs,
incompletely developed eggs, eggs covered with mold.)
5. Check the water for humidification everyday and fill it up as
shown in Fig - 4.
Stop supply of the water when styrofoam ball floats.
Do not reuse Vermiculite(incubation sand) after hatch.
If the incubation room is not properly controlled for high humidity (90~95%),
pour 75cc of water into four edges of the tray. ( See Fig. - 6)
And, pour 1000cc of water at the main body-2. [ Fig.- 3 ]
7. Operation Part
Menu Button
(Select Reptiles,
Incubation Termination)
Tray
Select Button
(Select Auto/Manual,
Pass to next stage)
Function Button
(Other function display,
Water Cap
Return to previous stage)
To facilitate water top-up
for the humidity control.
8. Display Part Explanation
ICON
1
Gecko
Power Cord
2
3
4
5
9. SET UP(Other Functions)
T.CAL
Temperature
Calibration
H.CAL
Humidity
Calibration
ALARM
Abnomal
High Alarm
ALARM
Abnomal
low Alarm
Unit
Light
Sound
ALL RESET
Factory setting
Info
75cc
75cc
75cc
75cc
[ Figure - 6 ]
[ Figure - 4 ]
Gecko
29.4
3Hr
90
0.0℃
NAME AND FUNCTION
ICON
Species of Reptiles
6
Heater Stop Display
Heater Operation Display
Humidification Stop Display
7
Humidification Operation Display
3Hr
8
Power Failure Notification
0.0℃
9
26.1
Daily Temperature Gap
Operation Display
10
WARNING
Be sure to read CAUTIONS. ( Calibration available after 5 Sec. )
Fatal Damage
with Incorrect Calibration !
Temp. calibration limits : -9.9℃ ~ +9.9℃
WARNING
Be sure to read CAUTIONS. ( Calibration available after 5 Sec.)
Fatal Damage
with Incorrect Calibration !
Alarm sounds when incubator temp. is higher than setting value
High
because of room temp. change or heating system disorder
Temp
* Setting Range : 0.0℃~5.0℃ (Default Setting : 0.0℃)
HiErr
Low
Alarm sounds when incubator temp. is lower than setting value
Temp
because of room temp. change or heating system disorder
* Setting Range : 0.0℃~5.0℃ (Default Setting : 0.0℃)
LoErr
o
Selecting Centigrade (
C) and Fahrenheit (
* Default Value : Centigrade (
o
C)
LCD Backlight management setting
* Always On : Always BackLight On
* Event On
: 20 Sec. ON with Key input
ON/OFF Setting for Melody, other alarms
* Default Value : ON
It returns to factory setting when you change the initial setting at discretion.
ALL RESET
Basic information of Incubator (versoin Indication)
Ver E 3.2
Vermiculite( incubation sand)
Vermiculite( incubation sand)
Water
Water
900cc
[ Figure - 1 ]
1000cc
③ ⓔ
[ Figure - 3 ]
[ Figure - 2 ]
Humidification
Heater Part
[ Figure - 5]
Up Button
Down Button
Input Button
(Enter input value,
Pass to next stage )
(Setting Value Check)
NAME AND FUNCTION
Reptile Icon Display
FAN Operation Display
Daily Temperature Gap
Setting Value Display
Current Temperature Display
Temperature Abnormal Display
Current Humidity Display
OFF
40
Humidification function OFF
o
F)
* Always Off : Always BackLight Off
* Default Value : Always On

Advertisement

loading
Need help?

Need help?

Do you have a question about the PX-20RD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rcom PX-20RD

  • Page 1 Ver E 3.2 6. Before use professional PX-20RD Digital Incubator Environment conditions of the incubation room 75cc 75cc www.R-com.co.kr for the installation of reptile incubator. ⓑ USER'S MANUAL ( Temp.: 22~25℃ / Humidity: 30~50% ) (Professional) Vermiculite( incubation sand) Vermiculite( incubation sand) 1.