North America Sales & Service www.RcomCo.com
▶ The Bird icon on the LCD display flickers and it switches to different types of bird by
pressing
+ or - button. Select the type of bird to incubate.
▶ After choosing the type of bird to incubate, keep pressing the OK button approximately 2
seconds when the icon flickers, then the internal lighting of the incubator turns on with a
Beep~ and the devices starts the operation.
▶ Incubator conditions are automatically and optimally adjusted.
Choosing the type of bird will set the proper incubation conditions as temperature, humidity
and rotation are automatically controlled and the user may modify the incubation condition
when necessary.
※ As the device controls the internal temperature checking the external environment due to artificial intelligence, therefore it may raise the temperature very
slowly in some sections.
Starting Manual (Other birds) Incubation
▶ This is a function where the temperature, humidity and egg rotation can be arbitrarily setup
by professionals skilled in incubation.
▶ In the initial display choose Other birds by pressing + or - button and press OK to enter to
the setup mode.
▶ The temperature setup, humidity, egg rotating angle, rotation cycle can be setup with
+ and - buttons and the setup values are saved by pressing the OK button.
[Temperature setup]
▶ TEMP (temperature) is briefly shown and 37.5℃ sign flickers.
Setup the desired temperature with + and - button and press OK to move to humidity
setup phase.
[Adjustment scope : 20 ~ 42℃ (68 ~ 107.6℉)]
[Default value : 37.5℃ (99.5℉)]
▶ If Candling sign (button) was pressed during setup you can go back to previous step.
[Humidity setup]
▶ HUMI(humidity) sign is briefly shown and 45% sign flickers.
Setup the humidity with + and - button and press OK to move to egg rotation angle setup
phase.
[Adjustment scope : RH 20 ~ 70%]
[Default value : RH 45%]
▶ When the humidity is setup below RH 20% the OFF sign indicates humidification function is
turned off.
▶ If Candling sign (button) was pressed during setup you can go back to previous step.
The setup humidity turns to RH 65% from 3 days before hatch. This is automatically programmed feature to help hatching and not a fault of the device.
The temperature and humidity are optimally adjusted according to international standards when launched from factory.
When necessary it can be reset but it is not recommendable to be directly adjusted by the user. When reset is necessary please contact the place
where you purchased the product.
The low price thermometer and hygrometer easily procurable in markets can be inaccurate in measurement value and may need frequent calibration,
therefore please use the exclusive thermo-hygrometer for birds. [Thermo-hygrometer exclusive for birds at www.RcomCo.com]
[Egg rotation angle setup]
▶ ANGL(Egg rotation angle) is briefly shown and 10s(seconds) sign flickers.
Setup the desired egg rotation time with + and - button and press OK to move to egg
rotation cycle setup phase.
[Adjustment scope : 0 ~ 60s(seconds) in 1 second as a unit, when setup as RND it shall be
operated randomly]
[Default value : 10s(seconds)]
▶ If Candling sign(button) was pressed during setup you can go back to previous step.
[Egg rotation cycle setup]
▶ INTV(Egg rotation cycle) is briefly shown and the 60m(minutes) sign flickers.
Setup the desired cycle with + and - button and press OK to move to cooling control cycle
setup phase.
[Adjustment scope : 10 ~ 360m(minutes) by scale of 10 minutes]
[Default value : 60m(minutes)]
The egg rotation is suspended 3 days before hatch.
This is automatically programmed to help hatching and not a fault of the device.
▶ If Candling sign(button) was pressed during setup you can go back to previous step.
Rcom Bird Egg Incubator Eco Pro Plus 10 User Manual