North America Sales & Service www.RcomCo.com
[Image 1-4]
① Cut the silicone tube exactly in 35mm and insert each of them to the nipple as shown in [Image 1-2].
(The initial product is assembled as ⓐ-1.)
② Cut the 1.5m silicone tube in two as stated in [Image 1-1] and insert each of them to the assembled nipple (ⓐ).
③ Assemble as [Image1-3] normal. If the silicone tube is not inserted onto the nipple correctly [Image 1-4] pumping performance is reduced.
④ As in Image [1-0] loose the 2 bolts in lower part of APS case and insert the [Image 1-3] to [Image 1-5] ⓑ.
⑤ Grab the side ⓒ of [Image 1-5] and pull the silicone tube and insert it to ⓓ. (The silicone tube must be firm but not too taut.)
⑥ Avoiding twisting the silicone tube, open the IN and OUT side, locate it in the hole and close the case. Verify if the silicone tube or cable is not stuck in the
case and tighten up the 2 bolts. Reference [Image 1-6].
How to control APS speed
▶ Easily control the volume of water through the APS.
▶ If you rotate adjustment to the right with a (+) shape driver the motor speed and pumping
volume are increased and when rotated reverse they're reduced. If forcibly rotated the
adjustment VR may be damaged.
▶ If the pumping volume is excessive the water may pour or leak from the moisture pad onto
the floor, therefore adjust as 1 drop of water for each 3 seconds from the moisture pad for
the best absorbency.
As the device controls the internal temperature checking the external environment due to
artificial intelligence, therefore it may raise the temperature very slowly at the beginning.
(In case of high humidity it may take dozens of hours.)
How to replace APS tube
▶ Damage silicone tubing will reduce the pumping volume or pumping may cease. In this case, please replace the silicone tubing.
The silicone tube sent with the initial product should be used in the product, also you may purchase it through Rcom or the place where you purchased
the
product. (Ø2.6 × 3.5)
If the pumping motor works but it does not produces water, or if there is louder noise than usual, the silicone tube may be aged, bent or blocked.
※ If the pump is not performing recheck the IN and OUT, verify if the motor rotates to the left [Image 1-5], and the silicone tube was cut exactly as 35mm
and
properly located as [Image 1-3].
How to maintain and clean APS
▶ Do not wash with water, please wipe with clean fabric material.
▶ The silicone tubes may adhere and block the tube hole. In this case, separate the tube from the device, eliminate water and furnish the tube preventing it
from
▶ The water pump can be dismantled. In case of reassembly due to blocked tube, please pull the blocked part of the silicone tube or open the interior of the
tube
3. INCUBATION / FUNCTION
SETUP
▶ When pressed Candling Sign (Button) during the Menu Setup the user may go back to the previous step.
Start of Automatic Incubation
▶ When connecting the power plug to socket the LCD display turns on and the device starts
to
work.
It may smell a little in first operation however this is normal.
Rcom Bird Egg Incubator Eco Pro Plus 10 User Manual
[Image 1-5]
Automatic Pumping System
(APS), See the video on how
to assemble and operate.
[Image 1-6]
1 drop every
3 seconds.
(1) Function setup
Need help?
Do you have a question about the PRO PLUS 10 and is the answer not in the manual?
Questions and answers