SAM 3-1
SAM 3 RASTER 'PROBLEM ISOLATION
Preprequisite:
To use this SAM you must be able to:
A. LOCATE the following components
•
crt/yoke
•
,crt socket
•
anode lead
•
yoke inline connector
•
monitor board and plug from control assembly
•
BRIGHTNESS/CONTRAST control assembly
•
J3 on power 'supply board
•
J5 on main logic board
r
•
monitor box shield assembly
\" "
•
G2 pot on monitor board (remove access lid, procedure 3)
Assumptions:
No raster observed after turning G2 pot and
BRIGHTNESS control fully clockwise.
(G2 must be readjusted per
procedure 16 at completion of testing.)
Remove option boards
installed in I/F 1 through I/F 3.
If raster can be obtained
after I/F 1 through I/F 3 boards are removed, reinstall one at a
time to determine which'onecausesthe problem.
All four power
supply LED's are lit.
If no 24 V LED go to step 001 of this SAM,
if no +5, +12 or -12 V
LED,~s
lit go to SAM 2, step 003.
6A-6
NOTE
The corrective actions in this SAM
assume that cables are good.
Before
replacing an item; check all
associated cables for damage or
shorts.
Before starting this SAM,
verify the 'following connections are
properly seated:
(check only after
terminal has been disconnected from
the outlet for 60 seconds).
•
anode lead from crt to monitor
board
•
yoke inline connector
•
socket at end of crt
•
monitor cable from BRIGHTNESS/
CONTRAST control to monitor board
connector
•
DC power cable from J3 power
supply board to P5 main logic
board
•
jumper for alpha/graphics is
installed correctly on main logic
board
62940034 D