SAM 3 RASTER 'PROBLEM ISOLATION
Preprequisite:
To use this SAM you must be able to:
A. LOCATE the following components
crt/yoke
,crt socket
anode lead
yoke inline connector
monitor board and plug from control assembly
BRIGHTNESS/CONTRAST control assembly
J3 on power 'supply board
J5 on main logic board
r
monitor box shield assembly
\" "
G2 pot on monitor board (remove access lid, procedure 3)
Assumptions:
No raster observed after turning G2 pot and
BRIGHTNESS control fully clockwise.
(G2 must be readjusted per
procedure 16 at completion of testing.)
Remove option boards
installed in I/F 1 through I/F 3.
If raster can be obtained
after I/F 1 through I/F 3 boards are removed, reinstall one at a
time to determine which'onecausesthe problem.
All four power
supply LED's are lit.
If no 24 V LED go to step 001 of this SAM,
if no +5, +12 or -12 V
LED,~s
lit go to SAM 2, step 003.
6A-6
NOTE
The corrective actions in this SAM
assume that cables are good.
Before
replacing an item; check all
associated cables for damage or
shorts.
Before starting this SAM,
verify the 'following connections are
properly seated:
(check only after
terminal has been disconnected from
the outlet for 60 seconds).
anode lead from crt to monitor
board
yoke inline connector
socket at end of crt
monitor cable from BRIGHTNESS/
CONTRAST control to monitor board
connector
DC power cable from J3 power
supply board to P5 main logic
board
jumper for alpha/graphics is
installed correctly on main logic
board
62940034 D