Mitsubishi Electric MELDAS 600 Series Instruction Manual page 29

Cnc maintenance tool
Hide thumbs Also See for MELDAS 600 Series:
Table of Contents

Advertisement

(1) Firmware
module model No.
Set the following range values according to the amplifier type.
Not registered
: Oxff
Servo
: 0x00 - Ox3f
Spindle
: 0x40 - Ox7f
(2) Module attributes
These are not used in the M6 downloading.
Normally set to 0.
(3) Bank A block No.
This is the block No. that includes the first bank (bank A) of the firmware module.
Block #O
0x00008000 - 0x0001 ffff
(relative address)
Block #l
0x00020000 - oxOoo37fff
(4) No. of banks
This is the No. of banks that include one firmware module.
Value from 1 to 4.
(5) System No.
g-character
ASCII code.
-
26
-