Operating Procedure In The Automatic Firmware Download Mode; Operation Proc&,Re - Mitsubishi Electric MELDAS 600 Series Instruction Manual

Cnc maintenance tool
Hide thumbs Also See for MELDAS 600 Series:
Table of Contents

Advertisement

6.4
Operating
procedure
in the automatic firmware
download
mode
6.4.1
Operation procedure
(1) Set the main CPU rotary switch to "9".
(2) Use the HR98x rotary switch 1 (1 to F) to select the firmware to be downloaded.
HR98x rotary switch
2
Selected firmware
0
Module list 1 firmware
1
Module list 1 firmware
2
Module list 2 firmware
3
Module list 3 firmware
;
Module list 14 firmware
F
Module list 15 firmware
* Module list No. :
Refer to "@I Module List" in the section titled "Operating procedure in the normal mode".
(3) Mount the maintenance tool on the actual device, then turn ON the CNC power.
(4) Start downloading the selected firmware.
The 7-segment LED of the CPU card (HR113/HRlll)
shows the download status.
Process
order
1
2
3
4
5
6
Program running (B bank)
P
7
Comparing
c
8
Correct completion
9
Completion error
e and error No.
+ Refer to the section titled 'Error information" for details on the display during errors.
Operation
LED display
Acquiring axis information
L
Erasing
E
Downloading
(A bank)
d
Program running (A bank)
P
Downloadina
(B bank)
d

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents