Mitsubishi Electric MELDAS 600 Series Instruction Manual page 15

Cnc maintenance tool
Hide thumbs Also See for MELDAS 600 Series:
Table of Contents

Advertisement

3) Compare
This command is used to compare the data in the designated memory with that on the backup
cassette.
The comparison
range size is the smaller of the designated
memory and the backup
cassette, When
designating
the block in the on-board
SRAM, the comparison size is
512KB
of on-
board SRAM.
The following shows an execution example.
>3 2 [Enter1
OnBoard
HR113B Sram <> C-Bus#2 HR4378 From
size=Ox80000
I
Compare
OK
... a)
a-* b)
-*- c)
*-- d)
a) The on-board SRAM data is compared with the data on the backup oassette.
b) The selected memory and backup cassette card name, memory type, and copy size is
displayed.
c) The data is being compared.
d) "OK" is displayed if the writing finishes correctly.
4)
Clear
This command is used to completely erase the designated memory. The memory is cleared (0 is
written) when the SRAM is designated. The memory is erased (Oxff written) when the FROM is
designated.
The following shows an execution example.
~4 3 rEnterI
CBus#l
HR437B From size=Ox400000
Clear
7 vES:Y(y) / NO:N(n)] --> y [Enter]
Erase
[>>>>>>>>>>>>>>S>]
OK
>
a) The FROM of the HR437B on C-BUS#l is erased.
b) The
card name, memory type, and clear size of the selected memory are displayed.
c) This is for confirming the execution. Clearing begins if Y is selected.
d) The FROM is erased. "[D>>]* shows that the operation is being executed.
e) "OK" is displayed if the writing finishes correctly.

Hide quick links: