Setting
Burst Tx Time
(Burst loads only)
Burst Idle Time
(Burst loads only)
Min Frm.Len Tx
(Fixed and Burst
loads only)
Max Frm.Len Tx
(Fixed and Burst
loads only)
Payload
(Fixed and Burst
loads only)
User 1 Data
(User 1 Data or
Seq + User 1
payloads only)
User 2 Data
(User 2 Data
payload only)
Src.IP Address
(Ping loads only)
Inverse ARP
(Ping loads only)
SmartClass E1 Tester User's Guide
Parameters
Time, ranging from 0.1 to 99.9 seconds, during which
E1/Datacom Tester
the
between idle time.
Note: To type a decimal point, use the asterisk (*) key
E1/Datacom Tester
on the
Time, ranging from 0.1 to 99.9 seconds, during which
E1/Datacom Tester
the
traffic between bursts.
Enter a value, from 5 to 9999 bytes, for the minimum
frame length to be transmitted.
Note: Assigning the same value to the Min Frame Len
Tx and Max Frame Len Tx will cause a fixed-length
frame to be transmitted.
Enter a value, from 5 to 9999 bytes, for the maximum
frame length to be transmitted.
Select the type of payload:
– Seq Test: Transmits a sequential count from 0 to
65,535. The remainder of the data is a fixed pattern.
Generated frames that are not of a length sufficient
to conform to RFC 2427 will not have a TTC Test
E1/Datacom Tester
Frame Header. The
received TTC test frames sequence numbers to
check for lost frames.
– User 1 Data: Transmits a user-defined hexidecimal
payload from 1 to 64 bytes long.
– User 2 Data: Transmits a user-defined hexidecimal
payload from 1 to 64 bytes long.
– Seq + User 1: Transmits the sequential count (0 to
65,535), and then the user-defined hexidecimal pay-
load.
Note: If you select the User 1 Data, User 2 Data, or Seq
+ User 1 payload, be certain to define the data.
Enter a hexidecimal value from 1 to 64 bytes long.
Enter a hexidecimal value from 1 to 64 bytes long.
Enter the IP address of the device the echo reply pack-
ets will be transmitted to.
NOTE: The E1/Datacom Tester only receives echo
messages if the source address of the incoming echo
message matches the destination address configured
on the E1/Datacom Tester.
Select one of the following:
– On. If you want the HST to use Inverse ARP to
determine the IP address of the equipment at the
other end of the Frame Relay link, select On.
– Off. If you specified a destination address for the
device you are pinging, select Off. Off is the default.
Chapter 5 Datacom Testing
Frame Relay testing
transmits a burst of traffic
keypad.
is idle and does not transmit
analyzes
67