Setting
Clock Source
(selectable only in Simulate
test mode)
Framing
MF Channel
Idle Code
(selectable only in Simulate
test mode)
5 From the Configuration menu, select Simulate Settings, and then specify
the values as described below:
Setting
Sequence Generation
Direction
DID Number
(selectable only for Forward
Direction and Express
Sequence Generation)
ANI Number
(selectable only for Forward
Direction and Express
Sequence Generation)
Category
(selectable only for Forward
Direction and Express
Sequence Generation)
Number of DIDs
(selectable only for Back-
ward Direction and Express
Sequence Generation)
SmartClass E1 Tester User's Guide
Testing MFC-R2 Signaling
Parameter
Select one of the following:
– Internal
– Rx1
– Rx2
– Ext. BNC
NOTE: If timing is lost, the SmartClass reverts
to internal timing.
Select one of the following:
– PCM30C
– PCM30
Select the MF channel or channels.
– To turn on the selected channels, use the
arrow keys to point at the channels/
timeslots you want to turn on, and then
press the # key to select it.
– If in Monitor/Bridge mode, you can select
multiple channels.
– If in Simulate mode, select only one chan-
nel.
When you have finished selecting channels,
press OK.
Enter an 8-bit binary string
Parameter
Select one of the following:
Express
Advanced
Select one of the following:
Forward
Backward
Enter the Direct Inward Dial (DID) number.
This is the phone number to be called.
Enter the Automatic Number Identification
(ANI) number. This is the caller's number, typ-
ically the E1Tester's own number.
Select a category. This is the E1Tester's own
category, from II-1 to II-15.
Specify the number of DIDs on the circuit.
Chapter 4 E1 Testing
47