Debugging; Vto Settings - Dahua Villa VTO Quick Start Manual

Version 3.1
Hide thumbs Also See for Villa VTO:
Table of Contents

Advertisement

2.2

Debugging

Carry out debugging to ensure that the device can realize basic network access, call and
monitoring functions after installation. Before debugging, please check whether the following
work has been completed.
Debugging personnel shall get familiar with relevant documents in advance, and get to
know device mounting, wiring and use.
Check whether there is short circuit or open circuit. Power on the device only after the
circuit is confirmed to be normal.
IP and no. (or room no.) of every VTO and VTH have been planned.

2.2.1 VTO Settings

For the first time, please initialize login password.
Please ensure that default IP addresses of PC and VTO are in the same network segment.
Default IP address of VTO is 192.168.1.110.
Step 1
Power on the device, and enter default IP address of VTO at the address bar of PC
browser. The system displays "Setting" interface, as shown in Figure 2-7.
Figure 2-6
16