hilscher NIOT-E-TIB100-GB-RE User Manual

hilscher NIOT-E-TIB100-GB-RE User Manual

Edge gateway
Hide thumbs Also See for NIOT-E-TIB100-GB-RE:
Table of Contents

Advertisement

Quick Links

User manual
Edge Gateway NIOT-E-TIB100-GB-RE
Passive Operating Mode
V1.1.1
Hilscher Gesellschaft für Systemautomation mbH
www.hilscher.com
DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NIOT-E-TIB100-GB-RE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for hilscher NIOT-E-TIB100-GB-RE

  • Page 1 User manual Edge Gateway NIOT-E-TIB100-GB-RE Passive Operating Mode V1.1.1 Hilscher Gesellschaft für Systemautomation mbH www.hilscher.com DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 2: Table Of Contents

    Step 6 - Check Signals in the Live-Data View .......... 67 4.3.7 Step 7 - Storing the generated configuration file (EtherCAT) ...... 68 EtherCAT (manual) ...................... 69 Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 3 Using a Docker container to access to the raw data............ 134 Performance considerations .................... 135 Only use a single passivefieldbus node ............... 135 Appendix.......................... 136 Legal notes........................ 136 Contacts.......................... 145 Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 4: Introduction

    OPC UA, Node-RED or Docker. List of revisions Revision Date Author Revision 2018-04-09 All sections created. Table 1: List of revisions Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 5: Passive Process Data Acquisition With The Edge Gateway

    Configurator". Configuration settings are provided by the tool „Passive Fieldbus Configurator“. Post-processing options are provided by Node-RED and OPC Ut. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 6: The Edge Gateway As Test Access Point

    Edge Gateway supplies such a Software-TAP without requiring any additional devices Figure 1: Edge Gateway as Software-TAP Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 7: Figure 2: Setup With Hardware-Tap

    Passive process data acquisition with the Edge Gateway 7/145 For the solution with Hardware-TAP, an additional device such as the Ethernet mirror TAP netMIRROR NMR-TFE-RE from Hilscher (Part number 7340.100) is required. The following figure explains how to connect the Hardware-TAP with the Edge Gateway: Figure 2: Setup with Hardware-TAP...
  • Page 8: Application Scenarios

    Software-based TAP behind a mirror port [} page 13]. This section should help you to decide which application scenario is best suited for your demands. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 9: Software-Based Tap

    Gateway, namely its use as a purely software-based TAP without use of any additional devices.The following picture explains its principle of operation. Figure 3: NIOT-E-TIB100-GB-RE - Passive mode as software TAP The advantages of this application scenario are: 1. SimplicityThis application scenario offers minimum effort in circuit design .
  • Page 10 You can avoid all of these disadvantages by connecting via a hardware- based TAP such as the netMIRROR, see next section. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 11: Hardware-Based Tap (Netmirror)

    At high demands on interruption-free operation, it makes sense to apply a hardware TAP such as the Ethernet mirror TAP netMIRROR NMR-TFE-RE from Hilscher as short-time link disruption and other back effects from the Edge Gateway to the system are excluded for this application scenario.
  • Page 12 100 Mbit/s. This minimizes the link-up time. See Communication settings in the Passive Fieldbus Configurator. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 13: Software-Based Tap Behind A Mirror Port

    13/145 2.2.3 Software-based TAP behind a mirror port Figure 5: NIOT-E-TIB100-GB-RE - Passive mode as software TAP at the morror port of a switch For PROFINET there is another application option by connecting the NIOT- E-TIB100-GB-RE with the mirror port of a switch. See following figure.
  • Page 14: Configuration For Passive Mode

    Within Node-RED, the fieldbus input node and the fieldbus output node provide a means for coupling the automation network in active mode of operation . Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 15: Figure 7: Inactive Mode Of Operation

    Is the Edge Gateway in the Passive Operation Mode, then the Network > Field menu in the Control Panel shows: Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 16: Figure 8: Passive Operation Mode - Operational Mode

    Passive Operation Mode, these nodes cannot be used. The passivefieldbus input node has to be used instead to connect to the automation network. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 17: Figure 9: Example: Switching To Active Mode Of Operation

    Node-RED or using OPC UA. Changes of the signal configuration cannot be accomplished within this mode. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 18: Figure 10: Switching From Mode Configuration Into The Mode Operational Of The Passive Mode (Example: Swiching From Configuration To Operational)

    ð The following message text appears on a light green background: Passive mode is successfully changed. The mode is being changed. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 19: Configuration Parameters And Project Files

    Configuration of control panel page Network->Field. Figure 12: Button "Upload" (part of the configuration page within the control panel) Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 20: Figure 13: Button "Download" (Part Of The Configuration Page Within The Control Panel)

    Configuration of control panel page Network->Field. Figure 14: Button "Remove" (part of the configuration page within the control panel) Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 21: Figure 15: Opc-Ua Settings Within The Control Panel, Page Network>Field

    URL Default: opc.tcp://127.0.0.1:4840/ UADiscovery Table 3: Input fields for communication settings of the OPC UA Server for Edge Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 22: Table 4: Input Fields For Limitation Settings Of The Opc Ua Server For Edge

    Settings for the Passive Operation Mode The checkbox Enable passive fieldbus the OPC UA Server for the passive operation mode. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 23: Figure 16: Safety Query When Storing The Opc Ua Server Configuration

    The changes are stored in the Edge Gateway now. However, they will get effective after the next restart of the Edge Gateway. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 24: Licensing

    OT interface and provides the received data for further processing via OPC UA, Node-RED or Docker. Table 6: License overview Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 25: Which Licenses Are Present In The Device

    For each license, it displays the license type (Column Type), a brief description (Column Description) and the expiration date (Column Expires) . Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 26: How To Order And Receive A License

    Ø Hilscher creates an individual license file for your Edge Gateway according to the information supplied by you. Ø Hilscher sends this file back to you as an attachment within the answer e-mail. Consequently, this license file has to be transferred into the Edge Gateway as described in section How to transfer a license into the device? [} page 27].
  • Page 27: How To Transfer A License Into The Device

    Licensing 27/145 How to transfer a license into the device? Load the individual license file received from Hilscher from your PC into the Edge Gateway. Do the upload as follows: Ø Open the Control Panel in a web browser. Ø Select System > License Manager.
  • Page 28: Use Cases

    PROFINET- network (Steps1 to 8) and upload this project file into the Edge Gateway then (Step9, see separate description Uploading the project file to the Edge Gateway [} page 114]). Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 29: Step 1 - Start The Passive Fieldbus Configurator

    - Passive Fieldbus Configurator. ð The entry screen of the Passive Fieldbus Configurator is displayed: Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 30: Step 2 - Creating An Empty Project

    Ê The GUI of the Passive Fieldbus Configurator is displayed. Figure 21: Empty GUI of the Passive Fieldbus Configurator Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 31: Step 3 - Adjust Basic Settings Of The Passive Fieldbus Configurator

    Figure 22: Side menu Ê The main menu is opened. Figure 23: main menu - Register card "Views" Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 32: Figure 24: Main Menu - Register Card "Device Assignment

    Ethernet data traffic and zthe interface configuration are displayed. 4. The formerly grayed ot menu entry Connect is activated. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 33: Figure 25: Error Message "The Connection To The Device Was Not Possible

    Select this option if working with an additional Hardware TAP. MBit/s and 100 MBit/s. Table 7: Settings for network speed Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 34: Step 4 - Loading The Gsdml Files

    Ø Within the network wizard, select PROFINET as network protocol within selection list Network protocol. Figure 29: Selection list Network protocol. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 35: Figure 30: Import Of Device Descriptions

    Passive Fieldbus Configurator. Figure 31: Imported device description within the item list of the Passive Fieldbus Configurator (Example) Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 36: Step 5 - Acquiring The Start-Up Of Profinet Communication

    Gateway could not be configured correctly. In this case, try again to configure the connection according to step 3. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 37: Step 6 - Signal Configuration

    Edge Gateway by OPC UA or shall be made available within Node- RED. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 38: Step7 - Check Signals In The Live-Data View

    Uploading the project file to the Edge Gateway [} page 114] uploading of this file onto the Edge Gateway and activating it is described. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 39: Profinet (Manual)

    PROFINET network (Steps 1 to 8) and upload this project file into the Edge Gateway then (Step 9, see separate description Uploading the project file to the Edge Gateway [} page 114]). Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 40: Step 1 - Start The Passive Fieldbus Configurator

    Ê The GUI of the Passive Fieldbus Configurator is displayed. Figure 34: Empty GUI of the Passive Fieldbus Configurator Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 41: Step 3 - Adjust Basic Settings Of The Passive Fieldbus Configurator

    Figure 36: main menu - Register card "Views" Ø Select the register card Device assignment. Figure 37: main menu - Register card "Device assignment" Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 42: Figure 38: Selection List Network Speed

    Select this option if working with an additional Hardware TAP. MBit/s and 100 MBit/s. Table 8: Settings for network speed Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 43: Step 4 - Loading The Gsdml Files

    Ø Within the network wizard, select PROFINET as network protocol within selection list Network protocol. Figure 41: Selection list Network protocol. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 44: Figure 42: Import Of Device Descriptions

    Passive Fieldbus Configurator. Figure 43: Imported device description within the item list of the Passive Fieldbus Configurator (Example) Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 45: Step 5 - Manual Configuration Of Profinet Io-Controller And -Devices

    Figure 44: Context menu entry “Add controller” Ø Choose the only menu entry Add controller. Ê The controller assistant is opened: Figure 45: Controller assistant Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 46: Figure 46: Context Menu Entry "Add Device

    Figure 46: Context menu entry "Add device" Ø Select the entry Add device Ê The device assistant is opened: Figure 47: Device assistant Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 47: Figure 48: Context Menu Entry "Add Module

    Ê The context menu is opened. Figure 48: Context menu entry "Add module" Ø Select the entry Addodule Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 48: Figure 49: Module Assistant

    An additional descriptive Text can be specified in field Infotext. Ø Click at Finish. ð Now, the module is configured. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 49: Figure 50: Context Menu Entry "Add Submodule

    Figure 51: First page of dialog "Submodule assistant". Ø Specify the desired name of the submodule (subslot) in the field Name. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 50: Figure 52: Second Page Of Dialog "Submodule Assistant

    The selection list Frames enables specifying of multiple process data frames, for instance one for the each data direction (input and output) at bidirectional submodules. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 51 There are two possibilities to configure a variable within the device configuration. Either you can load a GSDML file describing this variable or you perform the following steps: Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 52: Figure 53: Context Menu Entry "Add Variable

    Ø Select the entry Add variable Ê The variable assistant is opened: Figure 54: Variable Wizard - first page (Parameter) Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 53 IO Data Object. A non-negative value between 0 and 7 has to be specified here. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 54: Figure 55: Dialog Variable Wizard - Third Page (Normalization/Downsampling)

    Scale and then the Offset is added to the product. Scale Specify the factor Scale for the user-defined normalization here. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 55: Figure 56: Edit Custom Value Filter - Downsampling-Type And -Rate

    1 to 1000 Milliseconds. See the following figure. Figure 56: Edit custom value filter – Downsampling-Type and -Rate Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 56: Step 6 - Signal Configuration

    Edge Gateway by OPC-UA or transferred into the cloud by Node-RED. whether Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 57: Step 7 - Check Signals In The Live-Data View

    Uploading the project file to the Edge Gateway [} page 114] uploading of this file onto the Edge Gateway and activating it is described. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 58: Ethercat (Automatic)

    Figure 58: Wiring diagram for passive process data acquisition with the Edge Gateway NIOT-E-TIB100-GB-RE in EtherCAT networks Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 59: Step 1 - Program Start

    Create->New within the introductory menu.. Ê The (still empty) GUI of the Passive Fieldbus Configurator is displayed. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 60: Step 3 - Adjust Basic Settings Of The Passive Fieldbus Configurator

    Figure 59: Side menu Ê The main menu is opened. Figure 60: main menu - Register card "Views" Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 61: Figure 61: Main Menu - Register Card "Device Assignment

    Ethernet data traffic and zthe interface configuration are displayed. 4. The formerly grayed ot menu entry Connect is activated. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 62: Figure 62: Error Message "The Connection To The Device Was Not Possible

    Select this option if working with an additional Hardware TAP. MBit/s and 100 MBit/s. Table 9: Settings for network speed Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 63: Step 4 - Upload The Eni File

    Figure 65: First page of the Network Wizard for EtherCAT Ø Within the network wizard, select EtherCAT as network protocol. Figure 66: Selection of network protocol Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 64: Figure 67: Second Page Of The Network Wizard For Ethercat

    Select this option if not using an additional Hardware TAP. Table 10: Options for the data direction within an EtherCAT network Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 65: Figure 68: Ethercat Import

    ð The device descriptions contained within the ENI file are imported and integrated into the structure tree within the element list of the Passive Fieldbus Configurator. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 66: Step 5 - Signal Configuration

    Gateway only choose those methods for continuation of data processing, which you really need in your specific application. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 67: Step 6 - Check Signals In The Live-Data View

    Ê The data acquisition within the Passive Fieldbus Configurator has been started. In the Live View window you can watch the signals and tune your configuration if necessary. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 68: Step 7 - Storing The Generated Configuration File (Ethercat)

    Edge Gateway. In section Uploading the project file to the Edge Gateway [} page 114] uploading of this file onto the Edge Gateway and activating it there is described. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 69: Ethercat (Manual)

    EtherCAT- network (Steps1 to 8) and upload this project file into the Edge Gateway then (Step9, see separate description Uploading the project file to the Edge Gateway [} page 114]). Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 70: Step 1 - Start The Passive Fieldbus Configurator

    Create->New within the introductory menu.. Ê The (still empty) GUI of the Passive Fieldbus Configurator is displayed. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 71: Step 3 - Adjust Basic Settings Of The Passive Fieldbus Configurator

    Figure 73: main menu - Register card "Views" Ø Select the register card Device assignment. Figure 74: main menu - Register card "Device assignment" Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 72: Figure 75: Selection List Network Speed

    Select this option if working with an additional Hardware TAP. MBit/s and 100 MBit/s. Table 11: Settings for network speed Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 73: Step 4 - Configuration Of The Process Fieldbus Configurators For Ethercat

    Figure 77: First page of the Network Wizard for EtherCAT Ø Within the network wizard, select EtherCAT as network protocol. Figure 78: Selection of network protocol Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 74: Figure 79: Second Page Of The Network Wizard For Ethercat

    Select this option if not using an additional Hardware TAP. Table 12: Options for the data direction within an EtherCAT network Ø Click at Finish. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 75: Step 5 - Manual Configuration Of The Ethercat Network

    Ê Open the context menu of the master. Figure 80: Context menu for EtherCAT Master Ø Within the context menu, click at the entry Add device Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 76: Figure 81: Dialog „Add Slave - First Page (Name)

    Figure 82: Dialog Add slave - second page"(Parameter) Within the dialog Add slave, the following specifications concerning the configuration are made: Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 77: Table 13: Coding Of Parameter "Physics

    The allowed range of values for Vendor ID extends from 0 to 0x7FFFFFFF (0 up to 2.147.483.647). Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 78: Figure 83: Context Menu For Ethercat Master

    Ø Within the element list, rightclick at the master or slave under which the variable shall be added. Ê The context menu appears, see above. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 79: Figure 85: Variable Wizard - First Page

    The datatype of the variable You can find a list of suitable datatypes in List of supported Data Types for Variables. Unit The coreresponding unit of the variable Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 80: Table 14: Possible Selections Depending On Mode Of Operation

    APRW, ARMW, FPRW, FRMW, Input and Output are selectable commands BRW and LRW Table 14: Possible selections depending on mode of operation Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 81: Figure 86: Dialog Variable Wizard - Second Page

    Command name. ð The command is changed. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 82 For a WKC value unequal to the value specified here, the status is automatically set to invalid. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 83 The WKC value is automatically adjusted if another Edge Gateway installation location is chosen. The allowed range of values extends from 0 to 4294967295. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 84 The values of the logical address is specified as hexadecimal value. The allowed range of values extends from 0 to 0xFFFFFFFF. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 85: Figure 87: Dialog Variable Wizard - Third Page (Normalization/Downsampling)

    Ø Click at Finish in order to display the configured variable in your project. ð The entered configuration data for the variable are stored within the project. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 86: Figure 88: Edit Custom Value Filter - Downsampling-Type And -Rate

    1 to 1000 Milliseconds. See the following figure. Figure 88: Edit custom value filter – Downsampling-Type and -Rate Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 87: Step 6 - Signal Configuration

    Ê If the mouse button is released, a new entry with the name of the signal is displayed in window „Signal configuration“. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 88 Gateway only choose those methods for continuation of data processing, which you really need in your specific application. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 89: Step 7 - Check Signals In The Live-Data View

    Ê The data acquisition within the Passive Fieldbus Configurator has been started. In the Live View window you can watch the signals and tune your configuration if necessary. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 90: Step 8 - Storing The Generated Configuration File (Ethercat)

    Edge Gateway. In section Uploading the project file to the Edge Gateway [} page 114] uploading of this file onto the Edge Gateway and activating it there is described. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 91: Custom Value Filters

    If the project file has been generated, it finally has to be uploaded to the Edge Gateway as described in Uploading the project file to the Edge Gateway [} page 114]. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 92: Step 1 - Start The Passive Fieldbus Configurator

    Create->New in the introductory menu.. Ê The (still empty) GUI of the Passive Fieldbus Configurator is displayed. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 93: Step 3 - Adjust Basic Settings Of The Passive Fieldbus Configurator

    Figure 91: Side menu Ê The main menu is opened. Figure 92: main menu - Register card "Views" Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 94: Figure 93: Main Menu - Register Card "Device Assignment

    Ethernet data traffic and zthe interface configuration are displayed. 4. The formerly grayed ot menu entry Connect is activated. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 95: Step 4 - Define Filter Conditions For Custom-Value Filters

    Void (no logic operation, only a single filter value is used) and(AND operation) · Or(OR conjunction) · · not(Negation, only a single filter value is used) · xorExclusive-OR-conjunction) Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 96: Figure 95: Assignment Of The Four Filter Criteria To The Wireshark Trace

    Ethernet Frame must be checked whether it equals 1. Figure 95: Assignment of the four filter criteria to the Wireshark Trace Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 97: Figure 96: Specify Filter Name

    And for the relation as shown in the figure. Figure 97: Custom-value filters - Selection of logical function Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 98: Figure 98: Custom Value Filters

    Type, see figure: Figure 99: Custom value filters - Selection of Ethertype for recognition of Powerlink frames Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 99: Figure 100: Custom Value Filters

    Ø Here, you may write an optional comment into the input field Comment, for instance Detection of Powerlink frames. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 100: Figure 102: Specifying The Second Filter Criterion - Entering The Filter Condition

    Figure 102: Specifying the second filter criterion - Entering the filter condition Ø Below type select User-definedt uint8. Figure 103: Specifying the second filter criterion - Selection of User-defined uint8 Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 101: Figure 104: Specifying The Second Filter Criterion -Afdter Selection Of User-Defined Uint8

    Ê As soon as a valid value has been entered, the red frames around the mandatory input fields Value are displayed in grey. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 102: Figure 106: Specifying The Second Filter Criterion - Input Of The Offset

    Ø You may write an additional comment into the input field Comment, for instance Destination broadcast. ð Now the dialog looks as follows. Figure 107: Specifying the second filter criterion - Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 103: Figure 108: Specifying The Third Filter Criterion - Entering The Third Filter Condition

    Figure 108: Specifying the third filter criterion - Entering the third filter condition Ø Below type select User-definedt uint8. Figure 109: Specifying the second filter criterion - Selection of User-defined uint8 Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 104: Figure 110: Specifying The Third Filter Criterion -After Selection Of User-Defined Uint8

    Ê As soon as a valid value has been entered, the red frames around the mandatory input fields Value are displayed in grey. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 105: Figure 112: Specifying The Third Filter Criterion - Input Of The Offset

    Message type: Poll response. ð Now the dialog looks like this. Figure 113: Specifying the third filter criterion (with Wireshark trace) Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 106: Figure 114: Specifying The Fourth Filter Criterion - Entering The Filter Condition

    Figure 114: Specifying the fourth filter criterion - Entering the filter condition Ø Below type select User-definedt uint8. Figure 115: Specifying the fourth filter criterion - Selection of User-defined uint8 Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 107: Figure 116: Specifying The Fourth Filter Criterion - After Selection Of User-Defined Uint8

    Ø Here, you may write an optional comment into the input field Comment, for instance Source 1 (Controlled Node. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 108: Figure 117: Specifying The Flurth Filter Criterion - (With Wireshark Trace)

    Frame Quicktester are self-explaining if clicking at the i-signs within a circle adjacent to these controls. When doing so, additional explanatory texts about the controls are displayed. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 109: Figure 118: Custom-Value Filters - Specifications For Extracting The Values Out Of The

    Each incoming Ethernet frame is assigned a certain value by analysis of the frame contents using defined rules. Table 16: Custom-value Filters – Approaches to extraction Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 110: Figure 119: Custom-Value Filters - Specification For Normalization Of Acquired Data

    Ê The fourth page of the dialog Edit custom-value filters is opened now: Figure 119: Custom-value filters – Specification for normalization of acquired data Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 111 ð The entered configuration data for the variable are stored within the project. Ø Click at Finish. ð The custom-value filter just having been defined is stored. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 112: Step 5 - Signal Configuration

    Gateway only choose those methods for continuation of data processing, which you really need in your specific application. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 113: Step 6 - Check Signals In The Live-Data View

    Edge Gateway [} page 114] is described, how you can upload this file to the Edge Gateway and activate it there. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 114: Uploading The Project File To The Edge Gateway

    Ø Specify the name of the OPC-UA Server to be applied in the field Server name. Ø Additionally configure the Timeout time for transactions in field Transaction timeout. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 115: Figure 122: Opc Ua Configuration (Figure Only Shows A Part)

    Ê After your selection the project file is transferred to the Edge Gateway. However, the data acquisition has not yet been started. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 116: Figure 124: Switching To Operational Mode In Passive Mode Of Operation

    See Node-RED transfers process data into the Cloud [} page 127]. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 117: Error Handling

    Ø At Passive Mode select „Configuration“. Ø Repeat the assignment. ð Now the assignment of the IP address should beperformed successfully. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 118: Figure 126: Error Message "Parsing Error In

    In this case check the ENI file for correctness and evaluate the additional information concerning the error which might be shown in the output window of the Passive Fieldbus Configurator. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 119: Figure 128: Gsdml File Already Exists

    · selected ENI file. If you click at "Nein", the currently loaded ENI file will be preserved. · Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 120: Figure 130: A Module With Same Slot Number Already Exists

    Check, whether the correct subslot number is in use as a subslot with the specified number already exists. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 121: Figure 132: Wireshark Example For Codesys Eni-Import

    Configurator lto the Edge Gateway and commission it there, a new network connection to the Edge Gateway must be present. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 122: Further Processing Of The Process Data

    The following example explains the OPC UA-based access to the data acquired by the Edge Gateway in the passive mode. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 123: Selecting Signals For Opc Ua

    OPC UA Server in the Edge Gateway should provide. Figure 133: Selecting signals for OPC UA Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 124: Example: Access To The Edge Gateway Over Opc Ua Using The Client Ua Expert

    Approach Proceed as follows: Ø Start the UA Expert. Figure 134: Intro screen of OPC UA Client UA Expert Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 125: Figure 135: Context Menu Of The Ua Expert

    Ø Click at the entry Double click to Add Server below Custom Discovery. Ê The dialog box Enter Url is opened: Figure 137: Dialog box Enter Url in UA Expert Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 126 Hilscher. Note: Concerning this topic read the notes at the following link Secure connection. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 127: Node-Red Transfers Process Data Into The Cloud

    Fieldbus Configurator. Check Node-RED in the Signal Configuration window for signals for further processing in Node-RED. Figure 138: Selecting signals for Node-RED Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 128: The Input Node "Passivefieldbus

    Edge Gateway and consequential data drops. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 129 Ø Click at the input node passivefieldbus in order to display its properties and function description in register card Info. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 130: Figure 140: Edit Window For Specifying The Parameters

    Ø Click at Deploy in order to transfer the nodes still only existing in the editor to the Edge Gateway and to activate those there. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 131: Structure Of The Data Delivered By The Input Node

    "name": "et200sp.AQ 4xU/I ST V1.0.AQ 4xU/I ST V1.0.O-channel 0", "datatype": "INTEGER16" "valueList": [ "ts": "1508346006127776395", "val": 1, "state": "valid" "ts": "1508346006129766435", "val": 1, "state": "valid" Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 132: Table 20: Structure Of The Process Variables (Elements Of Json Array)

    Bit set (Valid). Value is valid Bit not set (Invalid): Value is invalid Table 21: Structure of the elements of the value list Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 133: Display Of Data Processing Status

    Node-RED. 2. Optimize the Node-RED-Flow for reduced processing time Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 134: Using A Docker Container To Access To The Raw Data

    Edge Gateway. An example for Docker including documentation is hosted in the Docker hub repository. The URL is: https://hub.docker.com/r/hilschernetiotedge/passive-fieldbus/ Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 135: Performance Considerations

    Node-RED flow, then you should work with a link node in order to provide the desired data access. Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 136: Appendix

    The manual delivered with the product shall apply. Under no circumstances shall Hilscher Gesellschaft für Systemautomation mbH be liable for direct, indirect, ancillary or subsequent damage, or for any loss of income, which may arise after use of the information contained herein.
  • Page 137 Appendix 137/145 Liability disclaimer The hardware and/or software was created and tested by Hilscher Gesellschaft für Systemautomation mbH with utmost care and is made available as is. No warranty can be assumed for the performance or flawlessness of the hardware and/or software under all application conditions and scenarios and the work results achieved by the user when using the hardware and/or software.
  • Page 138 Additional guarantees Although the hardware and software was developed and tested in-depth with greatest care, Hilscher Gesellschaft für Systemautomation mbH shall not assume any guarantee for the suitability thereof for any purpose that was not confirmed in writing. No guarantee can be granted whereby the...
  • Page 139 The customer hereby expressly acknowledges that this document contains trade secrets, information protected by copyright and other patent and ownership privileges as well as any related rights of Hilscher Gesellschaft für Systemautomation mbH. The customer agrees to treat as confidential all of the information made available to customer by Hilscher Gesellschaft für...
  • Page 140: List Of Figures

    NIOT-E-TIB100-GB-RE - Passive mode as software TAP........Figure 4: NIOT-E-TIB100-GB-RE with hardware TAP............11 Figure 5: NIOT-E-TIB100-GB-RE - Passive mode as software TAP at the morror port of a switch......................... 13 Figure 6: Active mode of operation..................14 Figure 7: Inactive mode of operation ...................
  • Page 141 - Register card "Views" ..............71 Figure 74: main menu - Register card "Device assignment" ..........71 Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 142 Specifying the third filter criterion - Input of the offset .......... 105 Figure 113: Specifying the third filter criterion (with Wireshark trace) ........105 Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 143 Edit passive fieldbus node..................128 Figure 140: Edit window for specifying the parameters............130 Figure 141: Example: Timing diagram..................133 Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 144: List Of Tables

    Structure of the elements of the value list............... 132 Table 22: Status of data processing in Node-RED ..............133 Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...
  • Page 145: Contacts

    Phone: +1 630-505-5301 E-mail: info@hilscher.it E-mail: info@hilscher.us Support Support Phone: +39 02 25007068 Phone: +1 630-505-5301 E-mail: it.support@hilscher.com E-mail: us.support@hilscher.com Edge Gateway NIOT-E-TIB100-GB-RE | Passive Operating Mode © Hilscher 2018 DOC180202UM01EN | Revision 1 | English | 2018-04 | Released | Public...

Table of Contents