1.1.1 Description of the contents This user manual describes hardware, technical data, installation and commissioning of the Hilscher netTAP gateway device NT 151-RE-RE for Real-Time Ethernet networks. This document also features step-by-step instructions on how to reset the netTAP device to its “factory settings” (a.k.a. “firmware recovery”) and how to use an SD memory card to copy configuration data from one device to another (a.k.a.
The manual delivered with the product shall apply. Under no circumstances shall Hilscher Gesellschaft für Systemautomation mbH be liable for direct, indirect, ancillary or subsequent damage, or for any loss of income, which may arise after use of the information contained herein.
Page 16
Introduction 16/92 Liability disclaimer The hardware and/or software was created and tested by Hilscher Gesellschaft für Systemautomation mbH with utmost care and is made available as is. No warranty can be assumed for the performance or flawlessness of the hardware and/or software under all application conditions and scenarios and the work results achieved by the user when using the hardware and/or software.
Page 17
Additional guarantees Although the hardware and software was developed and tested in-depth with greatest care, Hilscher Gesellschaft für Systemautomation mbH shall not assume any guarantee for the suitability thereof for any purpose that was not confirmed in writing. No guarantee can be granted whereby the...
Page 18
The customer hereby expressly acknowledges that this document contains trade secrets, information protected by copyright and other patent and ownership privileges as well as any related rights of Hilscher Gesellschaft für Systemautomation mbH. The customer agrees to treat as confidential all of the information made available to customer by Hilscher Gesellschaft für...
Technical knowledge is presumed. The user has to assure that all legal regulations are obeyed. Intended use The netTAP NT 151-RE-RE device described in this manual is a communication device connecting two separate Real-Time Ethernet networks with each other. The device thus serves as a “gateway” between the two networks.
24/92 3 Description Functionality The netTAP NT 151-RE-RE device is a communication gateway connecting two separate Real-Time Ethernet networks. The two networks can be either using the same (e. g. PROFINET IO to PROFINET IO) or two different RTE network systems protocols (e. g. EtherNet/IP to PROFINET IO).
Note: For the conversion of CC-Link IE Field Slave to PROFINET IO Device, Hilscher offers a separate netTAP with special hardware, i.e. the NT 151-CCIES-RE. For more information about this device, see user manual netTAP NT 151-CCIES-RE – CC-Link IE Field Slave to PROFINET IO-Device gateway, DOC180403UMxxEN.
Requirements 28/92 4 Requirements Technical requirements · The netTAP NT 151-RE-RE device is to be mounted on a DIN rail according to DIN EN 60715. · A suitable external power supply is required. · The voltage to be applied must be in the allowed range 24 V ± 6 V DC.
Device drawings and connectors 31/92 Device label Each netTAP NT 151-RE-RE carries a device type label providing the following information: Labelling of channels and LEDs of the connectors of the primary network at X2 MAC address at X2 * Device type ID...
Device drawings and connectors 33/92 Power supply connector The power supply of the netTAP NT 151-RE-RE has to be connected to pins 4 and 5 of the five-pole MINI COMBICON connector X1 (for identification, see position (21) in section Positions of the interfaces and LEDs [} page 30]) The power supply voltage must be 24 V DC ±...
USB interface (Mini-B USB) The USB interface (see position in section Positions of the interfaces and LEDs [} page 30]) is used for configuring the netTAP NT 151-RE-RE with SYCON.net (see operating instruction manual Configuration of Gateway and Proxy Devices, DOC081201OIxxEN) and for recovering the firmware (see section Using USB to recover firmware [} page 44]).
In case an SD memory card containing a valid configuration is inserted into the netTAP NT 151-RE-RE while a power-on cycle is being performed, all data stored on the card will be copied to the internal load memory of the device.
Using USB and ComProX2 to reset the device to its factory settings/ recover the firmware On the other hand, if you are using the Hilscher ComProX2 tool via USB, you can directly access the file system of the netTAP and overwrite the old defective firmware file with a fresh firmware file.
Using an SD memory card to reset the netTAP to its “factory settings” The netTAP NT 151-RE-RE can be reset to its factory settings by using the load memory image on an SD memory card. You will find the load memory image on the Gateway Solutions DVD in the Supplements &...
For this, you need a USB cable with a Mini USB connector and the Hilscher ComProX2 tool, which is stored on the Gateway Solutions DVD in the Supplements &...
Firmware recovery 45/92 Prerequisites The USB driver for Hilscher netTAP has been installed on the · configuration PC (the driver is included in the USB driver installation program stored on the Gateway Solutions DVD). The configuration PC has been connected to the netTAP device via ·...
SD memory card, FAT formatted. Note: The SD memory card is not included in the delivery of the netTAP device, but can be obtained from Hilscher, part number 1719.003. A configuration has been downloaded to the netTAP device. · The Windows PC/Notebook with SYCON.net and the netTAP device ·...
Ø In the menu, choose File > Open…to open an existing netTAP project. Ø In the Vendor tab of the Device Catalog (right window), open folder Hilscher GmbH > Gateway Stand-Alone Slave. Then select the device and drag & drop it onto the bus configuration line in the middle window.
List of figures 89/92 List of figures Figure 1: Data flow netTAP NT 151-RE-RE ................ 24 Figure 2: Outer dimensions of NT 151................. 29 Figure 3: Dimensions of Mini COMBICON power supply plug ..........29 Figure 4: Protocol stickers ....................32 Figure 5: Galvanic isolation of NT 151-RE-RE ..............
Page 91
LED states for the OpenModbusTCP protocol ............Table 46: LED state definitions for the OpenModbusTCP protocol ........Table 47: netTAP NT 151-RE-RE troubleshooting by LED ............ Table 48: Technical data netTAP NT 151-RE-RE ..............Table 49: Technical data PROFINET IO Controller protocol ..........
Need help?
Do you have a question about the netTAP NT 151-RE-RE and is the answer not in the manual?
Questions and answers