Omron 3G8F7-CRM21 User Manual page 98

Componet master board for pci bus/ compactpci bus
Table of Contents

Advertisement

Communications Control API
Argument
Returned value
Remarks
78
Type
Parameter
HANDLE
Handle
CPNT_SOFT
*SoftwareTable IN
WARE_TABLE
WORD
DataRate
It returns TRUE when the function succeeds.
It returns FALSE when an error occurs. The error details can be obtained with
the function GetLastError.
This function is used to start the communications cycles.
The function cannot be executed while the communications cycles are
running.
CPNT_SOFTWARE_TABLE structure
Type
Parameter
WORD
OutNode
WORD
InNode
WORD
BitOutNode
WORD
BitInNode
Direction
IN
Device handle obtained with the
function CPNT_Open
Specify the number of occupied
nodes.
IN
Specify the data rate.
0: 4 Mbps
1: 3 Mbps
2: 1.5 Mbps
3: 93.75 kbps
Description
Specify the maximum number of occupied Word
OUT Slave Units.
Settable range: 0 to 64
Specified the maximum number of occupied Word
IN Slave Units.
Settable range: 0 to 64
Specified the maximum number of occupied Bit
OUT Slave Units.
Settable range: 0 to 128
Specified the maximum number of occupied Bit IN
Slave Units.
Settable range: 0 to 128
Section A-3
Description

Advertisement

Table of Contents
loading

This manual is also suitable for:

3g8f8-crm21

Table of Contents