Omron 3G8F7-CRM21 User Manual page 102

Componet master board for pci bus/ compactpci bus
Table of Contents

Advertisement

Communications Control API
82
CPNT_REGIST_TABLE structure
Type
Parameter
WORD
RunSet
WORD
RegTim
WORD
RegSet
WORD
IoUnitInfo[384] Set the I/O size information.
Description
This is used to set the Registration table function.
Bit
Flag
0
Registration
table enabled
flag
1
All Registered
Slave
Participation
Standby flag
2 to 7 Reserved
area
8
Communications
cycle optimization
flag
9 to 15 Reserved area
This is the time to monitor participation of registered
Slave Units.
Set value in units of 10 ms,
Settable range: 1 to 65535
Setting it to 0 will select the default of 1000
(10000ms).
Checking items for the Registration Table
Bit
Flag
0
VendorCode
1
DeviceType
2
ProductCode
3
MajorRevision
4 to 5 Reserved area
See the "I/O size
information format" on the next page for the setting
items.
+0
Set Word IN0 size (1W)
to
+63
Set Word IN63 size (1W)
+64
Set Word OUT0 size (1W)
to
+127
Set Word OUT63 size (1W)
+128
Set Bit IN0 size (1W)
to
+255
Set Bit IN127 size (1W)
+256
Set Bit OUT0 size (1W)
to
+383
Set Bit OUT127 size (1W)
Section A-3
Description
Always set it to 1 (ON)
when the Registration
table is used.
0 (OFF): Disabled
1 (ON): Enabled
Set 0 (OFF).
0 (OFF): Disabled
1 (ON): Enabled
Set 0 (OFF).
Description
0 (OFF) : Not checked.
1 (ON) : Checked.
Set 0 (OFF).

Advertisement

Table of Contents
loading

This manual is also suitable for:

3g8f8-crm21

Table of Contents