Omron 3G8F7-CRM21 User Manual page 209

Componet master board for pci bus/ compactpci bus
Table of Contents

Advertisement

Preparing and Mounting Flat Connectors on the Cables
3. Pressure-Welding the Connector
Use a DWT-A01 Special Tool (Pliers) to pressure-weld and connect the cable.
3-1 Align the center (see arrow) of the connector cover with the center of
the pressure-welding block on the DWT-A01 Pliers.
Special Tool (Pliers)
3-2 Squeeze the Pliers firmly until the lock on the Connector clicks into
place.
Note •Do not pressure-weld the connector cover at the edge.
•Do not use the back of pressure-welding block to pressure-weld
the connector cover.
•Set the Connector in the correct orientation.
OK
NG
3-3 Confirm that it is properly pressure-welded as shown below:
No space here
Connector cover
NG
NG
Section E-4
189