Preparing and Mounting Flat Connectors on the Cables
Preparing and
Mounting the DCN5-
BR4 Flat Connector
Plugs
4-3 Confirm that the cable is properly pressure-welded as shown below:
No space here.
Names of Flat Connector Plug components
1. Cutting the Cable
At the tip of the cable, cut the cable perpendicular to the cable length.
To prevent short-circuiting, use a sharp cutting tool such as a nipper. After
cutting, confirm that there is no remaining wire coming out.
2. Mounting the Cable
2-1 Place the Cable on the Connector with its white line facing upward,
near the cover opening.
(Cover opening)
It must be locked.
Cover
White line
Confirm that the line colors at the end of the
cable are in the following order starting from
the left: red, white, blue, and black.