Shared Memory Area Specifications
Master Status
122
Offset
(Word)
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
+21
95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80
+22
111 110 109 108 107 106 105 104 103 102 101 100 99 98 97 96
+23
127 126 125 124 123 122 121 120 119 118 117 116 115 114 113 112
(These values are the corresponding part of each node address.)
+24
15 14 13 12 11 10
+25
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
+26
47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32
+27
63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48
Detailed format
Name
Access
Event only
Read
SlaveUnit flag
This stores the status of the CompoNet Master Board.
Data format
Offset address: 0x0408
Offset
(Word)
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
+0
+1
+2
+3
+4
+5
+6
+7
+8
Communication stop mode
Bit
Flags for Repeater Units
9
8
7
6
ON: A node that can use event only
OFF: Normal
Bit
Node causing a communications stop
StateStatus
Data rate
Communication cycle time
Maximum communications cycle time
Cumulative CRC reception errors
Cumulative code reception errors
Communication State
Section B-3
5
4
3
2
1
Description
Registration table mode
0

Advertisement