Preparing and Mounting Flat Connectors on the Cables
194
2-2 Hold the Cable to prevent dislocation. Close the cover to sandwich the
Cable.
3. Pressure-welding the Connector
Use a DWT-A02 Special Tool (Pliers) to pressure-weld and connect the Cable.
3-1 Place the Connector on the pressure-welding block of the DWT-A02
Special Tool (Pliers). Align the Connector side faces with the datum
shown in the picture below (shaded faces). Thus the center (see
arrow) of the connector cover is aligned with the center of the
pressure-welding block on the Pliers.
3-2 Squeeze the Pliers firmly until the lock on the Connector clicks into
place.
Special Tool (Pliers)
Datum to place the
Connector
Connector cover
Section E-4