Preparing and Mounting Flat Connectors on the Cables
Preparing and
Mounting the DCN4-
BR4 Flat Connector
Plugs
188
Names of Flat Connector Plug components
Cable labels
(Flat cable: black, blue/green, white, and red)
Black
Lock lever
1. Cutting the Cable
At the tip of the cable, cut the cable perpendicular to the cable length.
To prevent short-circuiting, use a sharp cutting tool such as a nipper. After
cutting, confirm that there is no remaining wire coming out.
2. Mounting the Cable
Confirm that the cable colors match the cable label colors shown on the Flat
Connector Plug. Insert the cable tip all the way into cover until the line shown
below. Through the transparent cover, confirm it is surely inserted all the way
into the back.
Confirm that the cable in inserted to this point.