Omron 3G8F7-CRM21 User Manual page 159

Componet master board for pci bus/ compactpci bus
Table of Contents

Advertisement

Shared Memory Area Specifications
Detailed format
Name
Access
Function setting
Read/Write Sets the Registration table function.
Registered Slave
Read/Write This is the time in which to monitor the participation
participation time
Checking items
Read/Write Sets the items to check in the Registration table.
for the
Registration Table
I/O size
Read/Write Sets the I/O size information.
information
Vendor Code
Read/Write Sets these flags when the relevant flag of the
Device Type
Read/Write
Product Code
Read/Write
Major Revision
Read/Write
Description
Bit
Flag
0
Registration
table enabled
flag
1
All Registered
Slave
Participation
Standby flag
2 to 7 Reserved
area
8
Communications
cycle optimization
flag
9 to 15 Reserved area
of registered Slave Units. The value can be set in
units of 10 ms.
Settable range: 1 to 65535
Setting it to 0 will select the default of 1000
(10000ms).
Bit
Flag
0
VendorCode
1
DeviceType
2
ProductCode
3
MajorRevision
4 to 5 Reserved area
See the I/O size information format in the following
page for the set content.
Registration table is set to check.
The values to be set are the ones in the Slave Unit
Identity object information.
Section B-3
Description
Set it to 1 (ON) when
the Registration tables
are used.
0 (OFF): Disabled
1 (ON): Enabled
Set 0 (OFF).
0 (OFF): Disabled
1 (ON): Enabled
Set 0 (OFF).
Description
0 (OFF) : Not checked.
1 (ON) : Checked.