Manual Operation - Jøtul GF 160 DV IPI Installation And Operation Instructions Manual

Direct vent gas stove
Table of Contents

Advertisement

139894 GF 160 DV IPI 12/17
Figure 15.1. GF 160 DV IPI Controls Compartment.
Burner Operation
Familiarize yourself with the controls of the GF 160 DV
IPI and be sure that anyone else using the appliance is
also familiar with the controls and operation procedures.
Always follow the Lighting Instructions on the inside back
cover of this manual and also located on the inside the
Controls Access Panel.
This appliance is equipped with an ignition device that
lights the pilot automatically. Do not try to light the pilot
by hand.
1. Set the Mode Switch to OFF. See fig. 15.1.
2. Confirm the stove is connected to 120VAC house current.
3. Mode Switch Function:
• ON / OFF - Use for manual control of the burner.
When set to ON, the pilot will light, followed by
burner ignition.
• REMOTE - Set for handheld transmitter control or
remote thermostatic control.
26
Inlet (Supply)
Pressure Port
OFF REMOTE ON
Mode
Switch
Manifold
Pressure Port
Gas Valve
Rating
Plate
Operation Instructions
Control Access Panel
Regulator
IFC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents