Jøtul GF 400 BF CE2 Installation And Operation Instructions Manual
Jøtul GF 400 BF CE2 Installation And Operation Instructions Manual

Jøtul GF 400 BF CE2 Installation And Operation Instructions Manual

Balanced flue gas stove

Advertisement

Quick Links

139810_R4 GF 400 BF CE2 7/18
Installation and

Operation Instructions

WARNING: If the information in
these instructions is not followed
exactly, a fire or explosion may
result causing property damage,
personal injury or death.
– Do not store or use gasoline or
other flammable vapors and liq-
uids in the vicinity of this or any
other appliance.
– WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical
switch; do not use any phone in
your building.
• Immediately call your gas
supplier from a neighbour's phone.
Follow the gas supplier's
instruction.
• If you cannot reach your gas
supplier, call the fire department.
– Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
1

Advertisement

Table of Contents
loading

Summary of Contents for Jøtul GF 400 BF CE2

  • Page 1: Operation Instructions

    139810_R4 GF 400 BF CE2 7/18 Installation and Operation Instructions WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. – Do not store or use gasoline or...
  • Page 2 139810_R4 GF 400 BF CE2 7/18 EU Gas Appliance Regulation (GAR) Company name: Jøtul North America, Inc. Postal address: 55 Hutcherson Drive Postcode and City Gorham, Maine Country United States of America Telephone number: +0 1 207 591 6601 e-mail address...
  • Page 3: Table Of Contents

    139810_R4 GF 400 BF CE2 7/18 Table of Contents 1. Technical Information ......4 2. General Information ......5 3. Safety Information .........5 4. Installer Information ......6 5. User Information ........10 6. Parts Illustrations and Lists ....12 7. Remote Control Operation ....18 8.
  • Page 4: Technical Information

    139810_R4 GF 400 BF CE2 7/18 1. Technical Information Technical Data Jøtul GF 400 BF CE2 PIN 0558CN1873 AT, BG, CH, CZ DK, EE, ES, FI GB, GR, HR, IE BE, FR Countries of Destination IT, LT, LV, NO, PT...
  • Page 5: General Information

    139810_R4 GF 400 BF CE2 7/18 2. General Information 3. Safety Precautions This product has been approved to the European This appliance must be installed in accordance with the   Standard EN 613:2000 and is in accordance with EC Gas rules in force.
  • Page 6: Installer Information

    The vent system must terminate outdoors. The vent system is a balanced system: 100% of the The GF 400 BF CE2 is designed as a freestanding combustion air is supplied from outside the house and appliance and as such does not require additional fixing.
  • Page 7: R4 Gf 400 Bf Ce2

    139810_R4 GF 400 BF CE2 7/18 Flueing Options Vent Restriction The GF 400 BF CE2 is capable of a variety of flueing Exhaust Restrictor configurations using an assortment of balanced flue The Exhaust Restrictor is an adjustable shutter located components and accessories illustrated on pages 20, page 17.
  • Page 8: Log Set Installation

    / district of installation. Log Set Installation • Copper tube shall conform to • BS EN 1057; or • BS EN The GF 400 BF CE2 log set must be installed before 13349. operating the burner. The log set includes five log pieces, •...
  • Page 9: Battery Installation

    139810_R4 GF 400 BF CE2 7/18 Commissioning Inspection of the Pilot Flame Battery Installation The pilot assembly flame should have two flames as The TESC valve requires three, AA alkaline batteries be shown in fig. 17. The rear flame should fully engulf the installed within the central battery compartment.
  • Page 10: User Information

    139810_R4 GF 400 BF CE2 7/18 5. User Information Operating Instructions Lighting Instructions Commissioning, Lighting NOTE! Odours may be present when using the stove for WARNING: THIS APPLIANCE the first time: FEATURES ELECTRONIC PILOT IGNITION. DO NOT When used for the first time and hot, the appliance ATTEMPT TO LIGHT THE PILOT will emit a harmless, non-toxic odour.
  • Page 11: Battery Replacement

    139810_R4 GF 400 BF CE2 7/18 Maintenance NOTE: If the appliance will not be used for an extended period, such as during summer or storage, disconnect The complete installation, which includes the gas supply, power by setting the valve Master switch to the Left the actual appliance and the vent system, must be (O).
  • Page 12: Parts Illustrations And Lists

    139810_R4 GF 400 BF CE2 7/18 6. Illustrations 100mm 673mm To Rear Wall Figure 1. 330mm 100mm 100mm Figure 3. 51 mm 724mm 51 mm 673mm Figure 4. Minimum 470 mm clearance to noncombustible material 737mm required to remove glass panel.
  • Page 13 139810_R4 GF 400 BF CE2 7/18 Figure 7. Flueing Configurations. Figure 7 c. Flue Arrangement 3 ANY VERTICAL TERMINATION: Vent Position B 600mm maximum horizontal run if verticle rise is between 500-995mm, (600mm is the supplied attached terminal length). Figure 7 a.
  • Page 14 139810_R4 GF 400 BF CE2 7/18 Figure 9. Figure 10. Right Log, PN 220647. Figure 12. Left Log, PN 220646. Figure 11. Rear Log, PN 220645. Figure 14. Cross Log, PN 220701. Figure 13. Middle Log, PN 220648. DO NOT...
  • Page 15 139810_R4 GF 400 BF CE2 7/18 Figure 16a. Valve assembly and fittings No° No° de pièce Description 226041 Valve Heat Shield 225944 Valve Bracket 17917 Screw, HWH SMA #8 x 1/2 SL Blk Oxide 117970 Bolt, Hex Cap M5 x 10 DIN 933 8.8 Plain 226036 Adaptor, 3/8”...
  • Page 16 139810_R4 GF 400 BF CE2 7/18 Battery Compartment Figure 18. Valve Controls Figure 19. Exterior components. 9. Rear Shroud 22498992 Cast Iron Matte Black Parts Paint 10. Gasket, Collar 129118 11. Screw, #8 x 13mm, 4 117917 1. Top Plate 10396292 12.
  • Page 17 139810_R4 GF 400 BF CE2 7/18 M82678 M82652 M82650 45° Adaptateur de conduit, 100 / 150 mm M82653 M82654 M82668 M87379 M87913 M30170 M82667 M82658 M82659 M82655 M87196 M82661 Figure 20. Muelink and Grol flue components. All balanced flue accessories include locking bands.
  • Page 18: Remote Control Operation

    139810_R4 GF 400 BF CE2 7/18 7. Remote Control Operation Before using the remote handset... Familiarize yourself with all the handset functions and complete the Remote Control Setup procedure described in this section. Handset Functions Insert two, AA batteries into the rear compartment or the handset.
  • Page 19 139810_R4 GF 400 BF CE2 7/18 Remote Control Setup After successful batteries 4. Setting the Hour installation, the Handset will display as shown in fig. 21. As • Press and release the + or – supplied, the handset is already...
  • Page 20 139810_R4 GF 400 BF CE2 7/18 8. Paging the handset 11. Sleep mode (Zzz) in Manual Operation If you have misplaced the handset (and it is in range of Sleep mode is used to set a period of time after which the the stove), you can page it by pressing the “...
  • Page 21 139810_R4 GF 400 BF CE2 7/18 14. Pairing the Remote Control Although the remote control is paired with the stove at the factory, it may become necessary to cancel the pairing and re-synchronize the two , follow the steps below.
  • Page 22: Warranty

    This warranty policy applies to gas products identified by the Jøtul 4) Labor or other costs associated with the repair of gas controls, plumb- trade name GF 400 BF CE2 as set forth below. ing, burners, log set, or sheet metal firebox beyond the warranty period.
  • Page 23: Service Record

    Annual service - year 9 Sign.: personnel. Company: Date: Model Name: Jøtul GF 400 BF CE2 Service details: Serial No.: Purchase Date: Annual service - year 10 Sign.: Company:...
  • Page 24 139810_R4 GF 400 BF CE2 7/18 This appliance must be installed in conformance with local and national building regulations. Before beginning the installation, it is important that these instructions be carefully read and understood. Jøtul maintains a policy of continual product development. Consequently, products may differ in specification, color, or type of accessories from those illustrated or described in various publications.

Table of Contents