Mounting Steps, External Housing - Vega VEGABAR 66 Operating Instructions Manual

Suspension pressure transmitter with certec measuring cell
Table of Contents

Advertisement

4 Mounting
Wall mounting
18
2. Insert the transmitter with connection tube or suspension cable
into the opening of the mounting bracket and counter nut
3. Fasten counter nut with SW 46 on the thread
Removal is carried out in reverse order.
4.7

Mounting steps, external housing

1. Mark the holes according to the following drilling template
2. Depending on the mounting surface, fasten the wall mounting
plate with 4 screws
Fig. 11: Drilling template - wall mounting plate
Tip:
Mount the wall mounting plate so that the cable entry of the socket
housing points downward. The socket housing can be displaced by
180° to the wall mounting plate.
Warning:
The four screws of the socket housing must only be hand screwed. A
torque > 5 Nm (3.688 lbf ft) can damage the wall mounting plate.
VEGABAR 66 • 4 ... 20 mA/HART - climate compensated
90 mm (3.54")
70 mm (2.76")
3mm
(0.12")
8 mm
(0.32")

Hide quick links: