6 Set up with the display and adjustment module PLICSCOM
Basic adjustment
▶
Basic adjustment
Display
Diagnostics
Service
Info
Unit
Unit of measurement
▼
bar
Temperature unit
▼
°C
Damping
1 s
Display
Basic adjustment
▶
Display
Diagnostics
Service
Info
Displayed value
▼
Pressure
Backlight
▼
Switched off
42
items in the operating instructions manual "Display and adjustment
module".
6.5
Menu schematic
Information:
Depending on the version and application, the highlighted menu
windows may not always be available.
1
1.1
Position correction
Offset
=
0.2 mbar
0000 mbar
1.5
Linearization curve
▼
Linear
2
▼
2.1
Displayed value
Scaled
2.4
VEGABAR 66 • 4 ... 20 mA/HART - climate compensated
1.2
Min. adjustment
000.0 %
=
0.0 mbar
P
0.0 mbar
1.6
Sensor-TAG
Sensor
2.1
Display unit
▼
Volume
▼
l
1.3
Max. adjustment
100.00 %
=
100.00 mbar
0.0 mbar
1.7
2.2
Scaling
0 % = 0.0
l
100 % = 100.0
l
1.4
2.3