Master/Slave Mode - Ledj LEDJ163 User Manual

Pf 35 profile spot
Table of Contents

Advertisement

DMX mode:
Operating in a DMX control mode environment gives the user the greatest flexibility when it comes
to customising or creating a show. In this mode you will be able to control each individual trait of the
fixture and each fixture independently.
To access the DMX address mode, press the "MENU" button on the top of the unit to show
"DMX MODE ADDR" on the LCD display. Now use the "UP" and "DOWN" buttons to set the required
DMX address. Press the "ENTER" button to show "DMX MODE CHAN" on the LCD display and use the
"UP" and "DOWN" buttons to select the required the DMX channel (1/2 or 3 selectable). Press the
"ENTER" button to confirm the setting. The dimming curve settings will now be displayed, use the "UP"
and "DOWN" buttons on the rear of the unit to select between "DMX MODE DELAY:01" ~
"DMX MODE DELAY:04". Press the "ENTER" button to confirm the setting.
To exit out of any of the above options, press the "MENU" button.
DELAY:01 - Linear
DELAY:02 - Square Law
1 channel mode:
Channel Value
Function
1
000-255 Dimmer (0-100%)
2 channel mode:
Channel Value
Function
1
000-255 Dimmer (0-100%)
2
000-015
No function
016-255
Strobe (slow-fast)

Master/slave mode:

To set the master unit, press the "MENU" button on the top of the master unit to select either the manu-
al mode of the fade in/out mode.
To set the other units in slave mode, press the "MENU" button on the top of the unit to show "SLAVE
MODE" on the LCD display. Press the "ENTER" button to confirm the setting.
To exit out of any of the above options, press the "MENU" button.
Please ensure that all slave units are set to the same DMX channel mode as the master unit.
www.prolight.co.uk
Operating instructions
DELAY:03 - Inverse Square Law
3 channel mode:
Channel Value
1
000-255 Dimmer (0-100%)
2
000-031
032-063 LED on
064-095 Strobe (slow-fast)
096-127
128-159
160-191
192-223
224-255
3
000-020 Linear (dimming curve)
021-040
041-060
061-080
081-255
PF 35 Profile Spot User Manual
DELAY:04 - S-Curve
Function
LED off
LED on
Strobe pulse (slow-fast)
LED on
Strobe random (slow-fast)
LED on
Square Law (dimming curve)
Inverse Square Law (dimming curve)
S-Curve (dimming curve)
Default dimming curve (set via menu)
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ledj164aLedj163aLedj164

Table of Contents