2.2 List of Commands
2.2.5
Instrument Information
Commands
Command
Description
_MFG
Outputs the instrument
manufacturer
Outputs the instrument's product
_INF
name
_COD
Outputs the instrument's basic
specifications
_VER
Outputs the instrument's firmware
version information
_OPT
Outputs the instrument's option
installation information
_TYP
Outputs the instrument's
temperature unit, and daylight
saving time installation information
_ERR
Outputs the instrument's error
number information
_UNS
Outputs the instrument's unit
configuration information
Outputs the instrument's unit
_UNR
configuration information
Outputs the instrument's module
_MDS
configuration information
_MDR
Outputs the instrument's module
configuration information
2.2.6
Conditions for Executing
Commands
A command can be executed only when the recorder can
execute the setting change or operation that the command
specifies. Commands are invalid in the following
circumstances.
• The recorder is not in a condition to accept the
operation.
For example, if the recorder is not recording, you
cannot write a message.
• If the recorder does not have the function or is not
using the function.
The "Description" column in section 2.2.1, "Setting
Commands" contains the recorder suffix codes that are
required for using the commands.
• If the login function is in use, the command cannot be
used at the user level that the user is logged in at.
• User restriction is placed on the operation.
The following table lists the commands that are invalid
according to the limitation types (p1 of the SOpeLimit
command or p2 of the SUserLimit command).
Limitation Type Invalid Command
Memory
ORec
Math
OMath
DataSave
OExecRec, OMTReset
Message
OMessage
Batch
OBatName, OBatComment,
OBatText
AlarmACK
OAlarmAck
Comm
OEMail, OIPApply,
OMBRestore, OSLMPRestore
2-10
DispOpe
Page
2-115
DateSet
ChangeSet
2-115
2-115
File
2-115
2-115
2-115
System
Out
2-115
CalibSet
2-115
2-115
ControlIN
2-115
ControlOUT
Tuning
2-115
Program
*1 Setting commands except for SHomeKind, SHomeMonitor,
SFavoriteKind, SFavoriteMonitor, Smonitor, SMultiPattern,
SMultiKind, and SCalibIO
(Note) Only when the advanced security function (/AS option)
is in use on instruments whose version is 2.02 or later.
*2 Can be specified with the SUserLimit command when
the advanced security function (/AS option) is in use on
instruments whose version is 2.02 or later.
*3 Cannot be executed if initialization items include
SECURITY or OTHERS items.
*4 Cannot be executed if load items include CALIB items.
*5 Cannot be executed if initialization items include CALIB
items.
• The command is not applicable to the model.
For commands that can be used only on certain
models, the models are listed in the "Description"
column in section 2.2.1, "Setting Commands," to
section 2.2.4, "Communication Control Commands."
(Examples: [GX/GP], [GM])
The applicable models for the following commands are
further reduced.
Command
SViewAngle
SMultiPattern GX20, GP20
SMultiKind
SHomeKind, SHomeMonitor,
SFavoriteKind,
SFavoriteMonitor, Smonitor,
SMultiPattern, SMultiKind,
ODispRate
OExecSNTP, OSetTime
*1
Sxxxx
, OLoadConf,
OLoadConfAll, Oinit
OCtrlLoadPAT,
OCtrlLoadPATAll
OLoadConf, OLoadConfAll,
OSaveConf, OSaveConfAll,
OCtrlLoadPAT, OCtrlSavePAT,
OCtrlLoadPATAll,
OCtrlSavePATAll, Fmedia
OInit, FSysConf (when p1
is specified)
OCmdRelay, OCommCh
*2
SCalibIO, SSchedule,
SScheduleText,
OLoadConfAll, OLoadConf
*5
OInit
OCtrlRL
OCtrlSR, OCtrlAM, OCtrlMO
OCtrlAT
OCtrlMODE, OCtrlHOLD,
OCtrlADV
(Note)
Applicable Models
GX10, GP10
GX20, GP20
*3
*4
,
IM 04L51B01-17EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gm10Gx20Gp20Gp10

Table of Contents