Display Settings - YOKOGAWA GX10 User Manual

Gx series; gp series; gm series; smartdac+ communication command
Hide thumbs Also See for GX10:
Table of Contents

Advertisement

SPrgColor
Program Control Loop Color
Sets the loop color
Syntax
SPrgColor,p1,p2,p3,p4
p1 Loop number
p2 R value of RGB colors (0 to 255)
p3 G value of RGB colors (0 to 255)
p4 B value of RGB colors (0 to 255)
Query
SPrgColor [,p1] ?
Example
Description
This command can be used when a PID control
module is installed and the program control function (/
PG option) is enabled.
For details on RGB values, see "Description" of the
SColorIO
command.
SPrgDispDetail
Auto Message Printout, Automatic Switch
To Program Operation Display, Other

Display Settings

Sets the detail settings for auto message printout, display
switch, and start of program operation to On or Off.
Syntax
SPrgDispDetail,p1,p2,p3
p1 Program Run/Reset message
(Off, On)
Off
On
p2 Automatic switch to program operation
display (Off, On)
Off
On
p3 Detail settings at start of program
operation (Off, On)
Off
On
Query
SPrgDispDetail [,p1] ?
Example
Set Program Run/Reset message to On,
automatic switch to program operation display
to Off, and Program RUN detail settings to On.
SPrgDispDetail,On,Off,On
Description
This command can be used when a PID control
module is installed and the program control function (/
PG option) is enabled.
p3 is a setting to set the start segment number and
starting time of program operation at the start of
program operation.
IM 04L51B01-17EN
Messages are not
displayed.
Messages are displayed.
Not switched to the program
operation display
Switched to the program
operation display
Detail settings are not used
(default value).
Detail settings are used.
SCtrlEventAct
Control Event Action
Sets a control event action
When p2 (type) is set to Off
Syntax
SCtrlEventAct,p1,p2
p1 Registration number (1 to 100)
p2 Type (Off)
When p2 (type) is set to DI, DO, or internal switch
Syntax
SCtrlEventAct,p1,p2p3,p4,p5,p6,p7,
p8,p9
p1 Registration number (1 to 100)
p2 Type (DI, DO, SW)
DI
DO
SW
p3 Number
When P2=SW: 1 to 100
When P2=DI or DO: 0001 to 6932
p4 Input/output type (In, Out)
In
Out
p5 Status output content or operation content
Varies depending on P2 (DI, DO, SW). See
the table below.
For operation with p5=SELECT (hold, advance, start
of program operation, stop of program operation)
p6 Pattern type (PATTERN_NO, WCONST)
PATTERN_
NO
WCONST
p7 Pattern number
p8 Loop type
LOOP_NO
WCONST
p9 Loop number
When p5 is set to a value other than those above
(table below)
p6 Empty
p7 Element number corresponding to p5
Loop number
PV/time event number (1 to 32)
Query
SCtrlEventAct [,p1]?
Example
Set All loop control operation to stop when the
internal switch number (SW1) becomes 0 to 1.
Use Control event action number 1.
SCtrlEventAct,1,SW,1,In,ALL_LP_
STOP_ACT
Description
This command can be used when a PID control
module is installed and the program control function (/
PG option) is enabled.
If you need multiple channels for p2 (event type) and
p5 (action), use DI/DO/SW in the same module. The
table below shows the number of used channels.
2.4 Setting Commands
DI
DO
Internal switch
Varies depending on P2
(DI, DO, SW). See the table
below.
Program pattern number
Variable constant W
(LOOP_NO, WCONST)
Loop number
Variable constant W
2-91
1
2
App

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gm10Gx20Gp20Gp10

Table of Contents