Mitsubishi Electric MR-D30 Instruction Manual page 135

Melservo series general-purpose ac servo functional safety unit
Hide thumbs Also See for MR-D30:
Table of Contents

Advertisement

5. PARAMETERS
No.
Symbol
PSD14
**SDIF3
Input device - Noise rejection filtering time DI3
Select a filtering time to reduce noise of DI3A (CN10A-5) and DI3B (CN10B-5).
Setting method is the same as [Pr. PSD12].
Setting
digit
_ _ x x
_ x _ _
x _ _ _
Incorrect setting of this parameter will trigger [AL. 7A.3]. Refer to section 7.2 for details.
PSD15
**SDIF4
Input device - Noise rejection filtering time DI4
Select a filtering time to reduce noise of DI4A (CN10A-14) and DI4B (CN10B-14).
Setting method is the same as [Pr. PSD12].
Setting
digit
_ _ x x
_ x _ _
x _ _ _
Incorrect setting of this parameter will trigger [AL. 7A.3]. Refer to section 7.2 for details.
PSD16
**SDIF5
Input device - Noise rejection filtering time DI5
Select a filtering time to reduce noise of DI5A (CN10A-6) and DI5B (CN10B-6).
Setting method is the same as [Pr. PSD12].
Setting
digit
_ _ x x
_ x _ _
x _ _ _
Incorrect setting of this parameter will trigger [AL. 7A.3]. Refer to section 7.2 for details.
PSD17
**SDIF6
Input device - Noise rejection filtering time DI6
Select a filtering time to reduce noise of DI6A (CN10A-15) and DI6B (CN10B-15).
Setting method is the same as [Pr. PSD12].
Setting
digit
_ _ x x
_ x _ _
x _ _ _
Incorrect setting of this parameter will trigger [AL. 7A.3]. Refer to section 7.2 for details.
Name and function
Explanation
Noise rejection filtering time DI3
Refer to table 5.5 for setting.
For manufacturer setting
Explanation
Noise rejection filtering time DI4
Refer to table 5.5 for setting.
For manufacturer setting
Explanation
Noise rejection filtering time DI5
Refer to table 5.5 for setting.
For manufacturer setting
Explanation
Noise rejection filtering time DI6
Refer to table 5.5 for setting.
For manufacturer setting
5 - 18
Initial
Setting
value
range
[unit]
Initial
Setting
value
range
01h
00h
to
05h
0h
0h
Initial
Setting
value
range
01h
00h
to
05h
0h
0h
Initial
Setting
value
range
01h
00h
to
05h
0h
0h
Initial
Setting
value
range
01h
00h
to
05h
0h
0h

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents