SiBE121021_C
Check Method 2
1. Press the center of the Temp button and the Mode button at the same time.
2. Select " 5C " (service check) with the Temp▲ or ▼ button.
3. Press the Mode button to enter the service check mode.
4. Press the Temp▲ or ▼ button and change the figure until you hear the sound of "beep" or "pi pi".
5. Diagnose by the sound.
Service Diagnosis
" 5C " is displayed on the LCD.
The figure of the ten's place blinks.
"pi" : The figure of the ten's place does not accord with the error code.
"pi pi" : The figure of the ten's place accords with the error code but the one's not.
"beep" : The both figures of the ten's and one's place accord with the error code.
(The figures indicated when you hear the "beep" sound are error code.
Refer to page 306, 307.)
Service Check Function
(R11669)
(R11821)
(R11670)
(R11671)