Download Print this page

Main Features; How To Control The Unit - ACME MH-640S-ELC User Manual

Intelligent scanner

Advertisement

B. MAIN FEATURES
• Voltage:AC 120V 60Hz or 230-250V 50/60Hz
• Bulb: ELC 24V 250W
• The unit is a DMX512 scanner. It features full DMX512 control, 14 gobos plus
open and 11 colors plus white, accurate focusable optics system and stepper
motor with blackout feature. Fan cooled.
• It can be operated by DMX512 control or can be used as an individual unit without
a control.
• It can be linked together in master/slave combination units, as many as required in
4 channels and run by built-in preprogrammed chase sequences automatically or
by sound activation through an internal microphone to create an intelligent effect.
• Please use a 3 pin XLR cable/plug when connecting them together.
• It features different preprogrammed chase patterns.
• Dimensions:500mm x 200mm x 155 mm / 19.69 in x 7.87 in x 6.1 in
• Weight:10 kg / 22 lbs
C. LAMP
ELC 24V 250W
• Always switch off the mains supply and never handle the lamp or luminaire when it
is hot.
• Do not touch the bulb with bare hands. If this does happen, clean the lamp with
denatured alcohol and wipe with a lint free cloth before installing.
D. HOW TO CONTROL THE UNIT
( 1 ) By universal DMX controller
The DMX512 is widely used in intelligent lighting control, with a maximum of 512
channels.
1
DMX512
1
DMX INPUT
3
2
Termination reduces signal errors and to avoid signal
transmission problems and interference. It is always
advisable to connect a DMX terminal.
(Resistance 120 ohm 1/4W) between pin2 (DMX-) and
pin3 (DMX+) of the last fixture.
5D
 A DMX512 system requires a controller, lighting equipment and cable. These are
connected together in a "daisy chain" with the terminator at the end. The cable
cannot be branched or split to a "Y" cable.
 The terminator requires a 90-120 Ohm 1/4 Watt resistor soldered between two
signal cables.
 The DMX512 uses a very high-speed signal. Inadequate or damaged cables, bad
solder joints or corroded connectors can easily distort the signal and shut down
the system. A reliable DMX512 system starts with good quality cables.
 Each lighting unit needs to have an address set to receive the data sent by the
controller. The address number is between 0-511. The end of the DMX512
system should be terminated reducing signal errors.
 3 pin XLR connectors are more popular than 5 pin XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
2
3
COMMON
DMX +
1
DMX OUTPUT
3
2
DMX -
4
120 ohm 1/4W
1
3
2

Advertisement

loading