When BCD instructions are used
Examples of wiring for displaying the current value of D100 on the 2-digit 7-segment display are given below.
■Example of program
SM400
BCD
D100 K2Y10
■Examples of wiring
• Sink wiring
The example is the wiring for the input/output of the FX5UC-32MT/D.
Transistor output (sink)
COM0
COM0
Y10
Y11
1
Fuse
• Source wiring
The example is the wiring for the input/output of the FX5UC-32MT/DSS.
+V0
+V0
Y10
Y11
1
Fuse
Y12
Y13
Y14
Y15
2
4
8
1
1
2
4
8
1
2
4
8
Transistor output (source)
Y12
Y13
Y14
Y15
2
4
8
1
1
2
4
8
1
2
4
8
FX5UC-32MT/D
Y16
Y17
7-segment display used for sink wiring
2
4
8
(for transistor output)
PLC
FX5UC-32MT/DSS
Y16
Y17
7-segment display used for source wiring
2
4
8
(for transistor output)
PLC
6.7 Examples of Wiring for Various Uses
7-segment display
+
Y
Signal
-
COM1
7-segment display
+
+V0
Y
Signal
-
6 WIRING