Power supply wiring example of FX5UC-32MT/DSS
*2
FX5-4DA-ADP
*2
FX5UC-32MT/DSS
FX5-C32EX/DS
FX5-C32ET/DSS
*2
FX5-C1PS-5V
FX5-C32EYT/DSS
FX5-CNV-IFC
S/S
FX5-16EX/ES
*1 The grounding resistance should be 100  or less.
*2 Using the same power supply to each module and extension adapters is recommended. When a different power supply is used to them,
turn on the power supply at the same time with the CPU module or earlier than the CPU module. When tuning off the power, confirm the
safety of the system and turn off the CPU module at the same time. Some extension modules may not have power supply terminals.
Power ON
PL
MC
Class D
*1
grounding
Fuse
MC
24 V DC
Power supply for loads connected
to PLC output terminals
For details of the emergency stop operation,
refer to "DESIGN PRECAUTIONS".
24 V DC
Circuit
protector
MC
Emergency
stop
MC
24 V DC
6 WIRING
6.4 Power Supply Wiring