Installing/mounting

4.3 Use according to specifications

4.3
Use according to specifications
"Use according to specifications" covers:
● Use within technical limits.
● Consideration of liquid specifications and references.
● Consideration of specifications as to installation, commissioning and maintenance.
Do NOT:
● Use the sensors as a footboard for installation purposes.
● Change the flow meter in any way. For e.g. decomposition of material in connection with
Note
If the flowmeter is not used according to the specifications, the manufacturer cannot be
held responsible for any resulting damage.
4.4

Application Guidelines

Basic Requirements
● Determine pipe material and dimensions.
● Avoid vertical pipes flowing in a downward direction.
● Avoid installation of sensors on the top and bottom of horizontal pipes, if possible.
● Select a location with the longest straight run of pipe.
● Identify upstream piping configuration (elbow, reducer, etc.).
● Pipe surface should be smooth and, if necessary, free of paint.
● Avoid pressure reduction components upstream.
● Avoid mounting on or near weld seams.
● Pipe must be full to achieve proper operation.
34
processing, welding and use of accessories and spare parts not approved by Siemens.
FUS1010 IP65 NEMA 4X & IP66 NEMA 7
Operating Instructions, 01/2013, A5E02951520-AC