Table A- 2 Input/Output Wiring (Tb2) - 7Me39400Al00 And 7Me39400Al01 I/O Module (For 7Me3500 Or 7Me3530 Only) - Siemens FUS1010 Operating Instructions Manual

Sitrans standard liquid ultrasonic flow meter
Hide thumbs Also See for FUS1010:
Table of Contents

Advertisement

Appendix
A.2 I/O Connections and Wiring
Figure A-1
Table A- 2
Input/Output Wiring (TB2) - 7ME39400AL00 and 7ME39400AL01 I/O Module (for 7ME3500 or 7ME3530 only)
Pin#
Signal
1
Vo1+
2
Vo1-
3
Vo2+
4
Vo2-
5
CGND
6
Io1+
7
Io1-
8
Io2+
9
Io2-
10
CGND
11
PG1
12
PG2
13
PG3
14
PG4
182
7ME39400AL00 and 7ME39400AL01 I/O Module
Description
Meter process variables
are assigned to individual
outputs under menu
control.
0 -5000 Hz Frequency
output; assignable.
Definition
0-10 Volt Analog Output
Ref. Ground
0-10 Volt Analog Output
Ref. Ground
Chassis GND
4-20mA Output 1
Isolated Return
4-20mA Output 2
Isolated Return
Chassis GND
Frequency Output 1
GND
Frequency Output 2
GND
Function
System outputs assignable and scalable
to flow related parameters. CGND is for
cable shield terminations.
4-20mA outputs also provide a fault
indication by dropping to 2mA if assigned
to flow rate and under fault conditions.
5V TTL
GND
5V TTL
GND
FUS1010 IP65 NEMA 4X & IP66 NEMA 7
Operating Instructions, 01/2013, A5E02951520-AC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fus1010 ip65 nema 4xFus1010 ip66 nema 7