Precautions For Use Of Parameters For Drive Programming; Parameters Affected By Rated Current (%) - Omron 3G3MX2 Series User Manual

Drive programming
Hide thumbs Also See for 3G3MX2 Series:
Table of Contents

Advertisement

9 LX inverter
9-6
Precautions for Use of Parameters
for Drive Programming
9-6-1

Parameters Affected by Rated Current (%)

Parameter
No.
b012
1st Electronic Thermal Level
b212
2nd Electronic Thermal Level
b016
Free Setting Electronic Thermal Current 1
b018
Free Setting Electronic Thermal Current 2
b020
Free Setting Electronic Thermal Current 3
b022
1st Overload Limit Level
b025
1st Overload Limit Level 2
C039
Low Current Detection Level
C041
1st Overload Warning Level
C111
1st Overload Warning Level 2
9 - 18
Description
Data
0.20 to 1.00 x Rated current
0.0 to Rated current
<Heavy load>
0.20 to 2.00 x Rated current
<Light load>
0.20 to 1.50 x Rated current
<Heavy load>
0.00 to 2.00 x Rated current
<Light load>
0.00 to 1.50 x Rated current
0.0: Function not active
<Heavy load>
0.00 to 2.00 x Rated current
<Light load>
0.00 to 1.50 x Rated current
<Heavy load>
0.00 to 2.00 x Rated current
<Light load>
0.00 to 1.50 x Rated current