6. PROGRAMMING FEATURES

Factory settings of the constants are shown as

Constant Set-up and Initialization

Constant selection/initialization (n01)
The following table describes the data which can be set or read when n01 is
set.
Unused constants among n01 to n79 are not displayed.
n01 Setting
Constant that can be set
0
n01
n01 to n79*
1
Fault history cleared
6
Not used
7
Initialize
12
Initialize (3-wire sequence)
13
* Excluding setting disabled constants.
Refer to page 63.
"EMM" appears on the LED display for one second and the set data returns to its initial
NOTE
values in the following cases :
(1) The set values of input terminal function selection 2 to 5 (n36 to n39) are the same.
(2) If the following conditions are not satisfied in the V/f pattern setting :
Max. output frequency (n09) Ä Max. voltage output frequency (n11)
For details, refer to "Adjusting torque according to application" (V/f pattern setting) on page 37.
(3) If the following conditions are not satisfied in the Jump frequency setting :
Jump frequency 2 (n50) Ã Jump frequency 1 (n49)
(4) If Frequency reference lower limit (n31) Ã Frequency reference upper limit (n30)
(5) If motor rated current (n32) Ã 120% of inverter rated current
36
Constant that can be referred
n01 to n79
n01 to n79
> Mid. output frequency (n12)
Ä Min. output frequency (n14)
in the tables.