9 LX inverter
Y(i)  value
Command
Outputs data to the output terminal variable in
units of bits.
Note The output terminal variable is a variable that controls the status of the inverter's output termi-
Set the Multi-function Output 11 to 13 Selection (C021 to C023) and the Multi-function Relay Output (RY) Func-
tion Selection (C026) to 35 to 41 (MO1 to MO7: General-purpose output).
<Assignment example>
Y(00)  MO1 (multi-function No. 35)
Y(01)  MO2 (multi-function No. 36)
Y(02)  MO3 (multi-function No. 37)
Y(03)  MO4 (multi-function No. 38)
Y(04)  MO5 (multi-function No. 39)
Y(05)  MO6 (multi-function No. 40)
Y(06)  MO7 (multi-function No. 41)
 Example
In the above example, the status of X(00) to X(02) is monitored with the parameter UMon(0) (d025), and X(02) is output to Y(00).
Block number
1
Assigns 0 to UBw.
2 to 4
Assigns the variables X(00) to X(02) to the variables UB(0) to UB(2).
5
Assigns UBw to UMon(0).
6
Assigns UB(2) to Y(00).
7
Jumps to the block 1: loop_ unconditionally.
9 - 14
Description
Flowchart method
Y(i) :
<value>
nal. The following settings are required. The numerical order of the output terminal variables
follows the numerical order of the set general-output numbers.
Flowchart
i: output terminal variable
(range 0 to 6)
Value: any variable or constant
Format
Text language method
Y(i) :  <value>
Operation
Drive Programming User's Manual (I580-E2)
Argument
Text